- Allen-Bradley
- ASHCROFT
- New & Featured Products - HPS high-purity pressure gauge with Reed Switch
- New & Featured Products - S1 Pressure Transducer
- New & Featured Products - ZT12 High Purity Pressure Transmitter
- New & Featured Products - ZX12 High Purity Pressure Transmitter
- Pressure Instruments - Accessories
- Pressure Instruments - Diaphragm Seals-Isolators
- Pressure Instruments - Pressure Gauges
- Pressure Instruments - Pressure Sensors (Transducers/Transmitters)
- Pressure Instruments - Pressure Switches
- Pressure Instruments - SMART Transmitter Assemblies
- Temperature Instruments - MultiPoint Temperature Sensors
- Temperature Instruments - OEM Temperature Sensors
- Temperature Instruments - RTDs
- Temperature Instruments - Temperature Switches
- Temperature Instruments - Thermocouples
- Temperature Instruments - Thermometers
- Temperature Instruments - Thermowells
- Test Instruments - Calibrators
- Test Instruments - Hand Pumps-Controllers
- Test Instruments - Hydraulic Testers
- Test Instruments - Test Gauges
- Cosel
- Euromag
- eYc
- Finetek
- Huba Control
- Koyo
- Maxwell
- MEKKO
- Prokits
- 3C Product Repair Tools
- Aid Tools
- Alignment Tools & Screwdrivers
- Ceramic Driver
- Crimpers
- Cutter
- Drill Bits
- Driver Set
- Electrical Pliers
- Fiber Optics
- Hex Key Wrenches
- Hex Nut Drivers
- Knives & Scissors
- Miscellaneous
- Plier
- Power Tools
- Precision Tweezers
- Punch Down Tools
- Socket Wrenches
- Soldering & Desoldering
- Storage Box
- Strippers
- Test Instruments
- VDE Insulation Tools
- Setra
- Siemens
- SIMEX
- Sondar
- SURE INSTRUMENTS
- Suto
- Tsuruga
- VAISALA
- VE-PURE
- WELTEM
- Winters Instruments
TECH IMPRO AUTOMATION SOLUTION SDN BHD
7263, 1st Floor, Lorong Chempa, 12200 Butterworth, Penang, Malaysia.
+6012-466 1514
eYc THM86/87 Industrial Grade Multifunction Dew Point Transmitter
Previous | 2 / 4 | Next |
Features : With temperature compensated and linear correction / Physical quantity & temperature linear correction output by computer program / Industrial class sensor comes with high accuracy, long-term stability,and anti-condensation function.
Input : Capacitive Humidity Sensor & Pt100Ω
Output : 0...20mA / 4...20mA / 0...5V / 0...10V
Linear accuracy ( at + 25°C ) : ±0.15°C ± 0.002 °C x tactual / ±3dp°C ± ( 0.02 % F.S / °C )
Temp. influence of body ( at + 25 °C ) : 0.02 % F.S. / °C
Display£ºOptional
¡ñAdditional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)
Description
¡ñ Industrial & multi-function£»Duct/Remote type£»Remote: 2-meter cable
¡ñ Temp. : -50 ... 80°C ; Dew point : -50 ... 60 dp°C ;
0 ... 20mA / 4 ... 20mA / 0 ... 1V / 0 ... 5V / 0 ... 10V
¡ñ With RS485 and MODBUS RTU communication interface that can play by program, data log, and analyze chart will be easy to monitoring.
¡ñ Physical parameters of outputs and range are programmable.
¡ñ Physical parameters are such as temperature, dew point, frost point, absolute humidity(ppm/v or ppm/w).
Specification
Measuring Range : Temperature : -50 ... 80°C ; Dew point : -50 ... 60 dp °C ; Frost point : -45 ... 0 fp°C
Accuracy ( at 25°C ) : Temperature : ±0.15°C±0.002°C x tactual ; dew point£º± 3 dp °C ± ( 0.02 % F.S / °C )
Temp. influence of body (at+25°C) : 0.02%F.S./°C
Output : 0 ... 20mA / 4 ... 20mA / 0 ... 1V / 0 ... 5V / 0 ... 10V
Signal Connection : 3-wire
Load Resistance : current output max. 500 Ω / voltage output min. 10 KΩ
output calibration ( ZERO & SPAN) : software
Power Supply : 8 ... 35V / 12 ... 30V
Protection rating : body IP65 ( probe : IP20 )
Application
¡ñ Monitoring for storeroom / crisper / agriculture / food industry.
¡ñ Monitoring for industrial process / air conditioning / environmental ventilation control .
¡ñ Temperature & humidity measuring in hospital / pharmaceutical industry / textile industry.
¡ñ Environmental monitoring for building / factory / clean room / Lab / weather station.
Input : Capacitive Humidity Sensor & Pt100Ω
Output : 0...20mA / 4...20mA / 0...5V / 0...10V
Linear accuracy ( at + 25°C ) : ±0.15°C ± 0.002 °C x tactual / ±3dp°C ± ( 0.02 % F.S / °C )
Temp. influence of body ( at + 25 °C ) : 0.02 % F.S. / °C
Display£ºOptional
¡ñAdditional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)
Description
¡ñ Industrial & multi-function£»Duct/Remote type£»Remote: 2-meter cable
¡ñ Temp. : -50 ... 80°C ; Dew point : -50 ... 60 dp°C ;
0 ... 20mA / 4 ... 20mA / 0 ... 1V / 0 ... 5V / 0 ... 10V
¡ñ With RS485 and MODBUS RTU communication interface that can play by program, data log, and analyze chart will be easy to monitoring.
¡ñ Physical parameters of outputs and range are programmable.
¡ñ Physical parameters are such as temperature, dew point, frost point, absolute humidity(ppm/v or ppm/w).
Specification
Measuring Range : Temperature : -50 ... 80°C ; Dew point : -50 ... 60 dp °C ; Frost point : -45 ... 0 fp°C
Accuracy ( at 25°C ) : Temperature : ±0.15°C±0.002°C x tactual ; dew point£º± 3 dp °C ± ( 0.02 % F.S / °C )
Temp. influence of body (at+25°C) : 0.02%F.S./°C
Output : 0 ... 20mA / 4 ... 20mA / 0 ... 1V / 0 ... 5V / 0 ... 10V
Signal Connection : 3-wire
Load Resistance : current output max. 500 Ω / voltage output min. 10 KΩ
output calibration ( ZERO & SPAN) : software
Power Supply : 8 ... 35V / 12 ... 30V
Protection rating : body IP65 ( probe : IP20 )
Application
¡ñ Monitoring for storeroom / crisper / agriculture / food industry.
¡ñ Monitoring for industrial process / air conditioning / environmental ventilation control .
¡ñ Temperature & humidity measuring in hospital / pharmaceutical industry / textile industry.
¡ñ Environmental monitoring for building / factory / clean room / Lab / weather station.