TECH IMPRO AUTOMATION SOLUTION SDN BHD
7263, 1st Floor, Lorong Chempa, 12200 Butterworth, Penang, Malaysia.
+6012-466 1514

eYc THS88 Industrial High Pressure Low Humidity Dew Point Transmitter

Previous 1 / 4 Next

eYc THS88 Industrial High Pressure Low Humidity Dew Point Transmitter Dew Point Transmitter Temperature & Humidity / Dew Point eYc
Quantity
Add Quotation


Input£ºCapacitive humidity sensor & Pt100
Output£ºStandard RS-485 & 1 analog output
Linear accuracy£º±2 dp°C(at +25°C)±(0.02%F.S. / °C)
Operating range of dew point£º-60 ... +60 dp°C
Max. Scaling range£ºDew point£º-100 ... +60 dp°C
Pressure resistance£º16 bar
¡ñYUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation£º3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA
 
Description

Capable of temperature compensation and linear calibration
Industrial sensor with non-condensing. Pressure resistance£º16 bar
High pressure, low humidity. Dew point scaling range£º-100 ... +60 dp°C
Standard Modbus RTU protocol, RS-485 communication interface
High accuracy and long-term stability
More size of connector for different environment
Analog output£º0 ... 1 V / 0 ... 5 V / 1 ... 5 V / 0 ... 10 V / 2 ... 10 V / 0 ... 20 mA / 4 ... 20 mA
Free programmable software which can adjust dew point range and provide more physical quantities
such as dew point, frost point, absolute humidity and so on
 
Specification

Input type£ºCapacitive humidity sensor & Pt100
Operating range of dew point£º-60 ... +60 dp°C
Max. scaling range£ºDew point£º-100 ... +60 dp°C
Dew point switch to another physical quantity range£ºFrost point£º-60 ... 0 fp°C£»Absolute humid.(Volume)0 ... 50000 ppm/v£»Absolute humid.(Weight)0 ... 50000 ppm/w
Output signal£ºStandard RS-485 & 1 analog output / 0 ... 20 mA / 4 ... 20 mA / 0 ... 1 V / 0 ... 5 V / 0 ... 10 V
Signal connection£º3-wire
Modbus£ºStandard RS-485 & 1 analog output
Linear accuracy£º±2 dp°C(at +25°C)±(0.02%F.S. / °C) (Operating range of dew point£º-60 ... +60 dp°C)
Load resistance£ºCurrent output£ºMax.500 Ω£»Voltage output£ºMin.10 KΩ
Output calibration (ZERO & SPAN) adjustment range£ºSoftware
Response time t90 (Temp. at+25°C)£º£¼20 sec
Power supply£ºDC 8 ... 35 V&AC 10 ... 30 V
Current consumption£ºDC 24 V, 50 mA
Electrical connection£ºM12 connector
Medium£ºAir
Operating Temp. for housing£º-40 ... +60°C
Operating Humid. for housing£º0 ... 95%RH (Non-condensing)
Operating Temp. for probe£º-40 ... +60°C
Storage temperature£º-25 ... +60°C
Pressure resistance£º16 bar
Installation£ºMetal connector
IP rating£ºIP65(Probe£ºIP20)
Electrical protection£º¡ö Polarity protection ¡ö Over-voltage ¡ö Short-circuit
Housing£ºS.S.(SUS304)
Probe£ºS.S.(SUS304)£»SUS sintered filter(SUS316)
Weight£º233 g
Factory setting
Measuring range of dew point£º-100 ... +20°C
Output£º4 ... 20 mA& standard RS-485
 
Application

Compressed air system / Freezer / Adsorption machine / Plastic dryer / Industrial drying process / Paper / Chemical process monitoring


Please leave your enquiry here, we will reply as soon as possible.