Siemens SITRANS FC MASS 2100 DI 1.5

Previous 7 / 12 Next

Siemens SITRANS FC MASS 2100 DI 1.5 Coriolis Flow Measurement Flow Measurement Siemens
Quantity
Add Quotation


The SITRANS FC MASS 2100 DI 1.5 has demonstrated superior performance in numerous applications and field trials relating to mass flow- and density accuracy and turn down ratio. The single continuous tube design without internal welds, reductions or flow splitters, offers optimal hygiene, safety and CIP cleanability for food & beverage and pharmaceutical applications. This makes the SITRANS FC MASS 2100 DI 1.5 the preferred meter for research and development and mini-plant applications for liquid or gas measurement, where measuring very small quantities (e.g. drops per hour) is important.

In order to make a complete flowmeter, the SITRANS FC MASS 2100 flow sensor must be combined with one of the following MASS transmitters:

 

SITRANS FCT030: For general industry applications
SITRANS FCT010: For OEMs and skids in applications where space is limited
SITRANS FCT070: For SIMATIC ET 200SP distributed I/O 
 

Benefits

  • Markets smallest and most stable zero point - Dual-drive pick-up and driver construction facilitate ultra low-weight pipe construction
  •  Optimal lifetime - Markets biggest wall thickness,corrosion resistent and high pressure durability
  •  Plug & Play - Multiplug electrical connector and SENSORPROM facilitate cost efficient installation and commissioning
  •  Enhanced safety - standard intrinsically safe EEx ia design
  • Outstanding accuracy - 4-wire Pt1000 temperature measurement for reliability in mass flow, density and % fraction

Detail

Measuring range
   From 0 to 30 kg/h (0 to 66 lb/h)
Nominal size
   DI 1.5 (1/16'')
Accuracy
   ≤ 0.1 % of rate
Nominal pressure
   Liquid pressure max 365 bar / max 5294 psi (Hastelloy)
   Liquid pressure max 230 bar / max 3330 psi (Stainless steel)
Medium temperature
   From -50 to 180 °C  (-58 to 356 °F)
Sensor design
   One tube bended
Enclosure
   IP65 (NEMA 4)
Approvals
   EEx (ia) IIC T3-T6
Typical applications: Dosing in the chemical industry (dosing of chemicals), food & beverage industry (concentrates, ketchup, pastes) and pharmaceutical industry (preparations, dialysis liquids).