TECH IMPRO AUTOMATION SOLUTION SDN BHD
7263, 1st Floor, Lorong Chempa, 12200 Butterworth, Penang, Malaysia.
+6012-466 1514

SIMEX STI-94

Previous 4 / 8 Next

SIMEX STI-94 Ratemeters / Tachometers Counters  SIMEX
Quantity
Add Quotation


  • pulse rate / period meter
  • rotational / linear speed control
  • revolution / movement period control
  • 0, 2 or 4 REL / OC outputs
  • analogue output: active or passive, power supply output: 24V DC
  • RS-485 / Modbus RTU
  • ''over'' signalling when the measuring range is exceeded
  • free configuration software S-Config
Description

The STI-94 tachometers are designed to control rotational or linear speed of moving objects. The device is also able to measure frequency. As an additional advantage the device can convert the rotational / linear speed into inverse values, and to display the single revolution period or process duration. The REL / OC control outputs can be programmed depending on the instantaneous value of rotational speed. Additionally the counter may be equipped with analogue outputs, according to the customer selection: active current output, passive isolated current output or active voltage output. The counter can be configured with the local keyboard or free S-Config software via the RS-485 communication port.
 

Specification
Number of inputs
1
Input type
pulse
Input levels
low: 0...1V; high: 10...30V
Input frequency
1,5...50 kHz
Output type
depends on configuration:
relay I=1A, U=30V DC/250V AC (cosø=1)
Open Collector: I=30 mA, U=30V DC, P=100 mW
0/4...20 mA: active current, operating range 0...24 mA max., load resistance 700 Ω max., resolution 13 bit
4...20 mA: passive current, isolated, operating range 2,8...24 mA max., load resistance 600 Ω@24VDC, resolution 13 bit
0/1...5V, 0/2...10V: active voltage, operating range 0...11V max., load resistance min. 2000 Ω, resolution 13 bit
Measurement unit
revolutions per second, per minute, per hour
Measurement method
electrical, pulse
Power supply
16...35V AC, 19...50V DC
85..260V AC/DC
Display
LED, 6 x 13 mm, red
Communication Interface
RS-485 / Modbus RTU
Transmission parameters
1200...115200 bit/s, 8N1 / 8N2
Operating temperature
0...+50°C
-20…+50°C
Protection class
IP 20 (case and connection clips)
IP 65 (front)
optional integrated frame for panel cut-out sealing
Case material
NORYL-GFN2S E1
Mounting
panel
Case dimensions
96 x 48 x 100 mm

Please leave your enquiry here, we will reply as soon as possible.