- Allen-Bradley
- ASHCROFT
- New & Featured Products - HPS high-purity pressure gauge with Reed Switch
- New & Featured Products - S1 Pressure Transducer
- New & Featured Products - ZT12 High Purity Pressure Transmitter
- New & Featured Products - ZX12 High Purity Pressure Transmitter
- Pressure Instruments - Accessories
- Pressure Instruments - Diaphragm Seals-Isolators
- Pressure Instruments - Pressure Gauges
- Pressure Instruments - Pressure Sensors (Transducers/Transmitters)
- Pressure Instruments - Pressure Switches
- Pressure Instruments - SMART Transmitter Assemblies
- Temperature Instruments - MultiPoint Temperature Sensors
- Temperature Instruments - OEM Temperature Sensors
- Temperature Instruments - RTDs
- Temperature Instruments - Temperature Switches
- Temperature Instruments - Thermocouples
- Temperature Instruments - Thermometers
- Temperature Instruments - Thermowells
- Test Instruments - Calibrators
- Test Instruments - Hand Pumps-Controllers
- Test Instruments - Hydraulic Testers
- Test Instruments - Test Gauges
- Cosel
- Euromag
- eYc
- Finetek
- Huba Control
- Koyo
- Maxwell
- MEKKO
- Prokits
- 3C Product Repair Tools
- Aid Tools
- Alignment Tools & Screwdrivers
- Ceramic Driver
- Crimpers
- Cutter
- Drill Bits
- Driver Set
- Electrical Pliers
- Fiber Optics
- Hex Key Wrenches
- Hex Nut Drivers
- Knives & Scissors
- Miscellaneous
- Plier
- Power Tools
- Precision Tweezers
- Punch Down Tools
- Socket Wrenches
- Soldering & Desoldering
- Storage Box
- Strippers
- Test Instruments
- VDE Insulation Tools
- Setra
- Siemens
- SIMEX
- Sondar
- SURE INSTRUMENTS
- Suto
- Tsuruga
- VAISALA
- VE-PURE
- WELTEM
- Winters Instruments
TECH IMPRO AUTOMATION SOLUTION SDN BHD
7263, 1st Floor, Lorong Chempa, 12200 Butterworth, Penang, Malaysia.
+6012-466 1514
COSEL AME1200F
Previous | 8 / 11 | Next |
Rated Input: 85 - 264VAC 1Φ
Rated Output Wattage: 1200W
Slots: 6
Rated Output Voltage: 3.3V,5V,7.5V,12V,15V,24V,36V,48V,24V/24V
• Low profile(41mm, 1.61inch=meet to 1U height)
• Universal input (85-264VAC)
• For medical electrical equipment
ˇˇ(ANSI/AAMI ES60601-1, EN60601-1 3rd, IEC60601-1-2 4th Ed.)
• Medical Isolation Grade 2MOPP
• With AUX output 5V 1A
• Global Inhibit, Remote ON/OFF control, alarm
• Output connector is available (Option: -J2Ł©
• Monitoring function and some parameter changes by communication are available(Option: -I3, -I).
Please refer to Configuration-Model Name Construction in Instruction manual for Order Name.
Order Name is required to create by the above menu.
ˇöModel Name
(2Ł© Abbreviation for output power of AME series
12: AME1200F(AM12Ł©
(3Ł© Slot 6 Output module
(4Ł© Slot 5 Output module
(5Ł© Slot 4 Output module
(6Ł© Slot 3 Output module
(7Ł© Slot 2 Output module
(8Ł© Slot 1 Output module
(9Ł© Parallel code
(10Ł©Series code
(11) Option
A: 12V/0.1A AUX instead of 5V1A
R: Reversed logic remote on/off
J2: Output connector type
J3: CN1/CN2/CN3 Molex connectors
C: with Coating
F3: Revers air exhaust type
G: Low leakage current
I3: with Extented-UART interface
I: with PMBus interface
Refer to instruction manual 6.1
*The number of slot is different depending on the model.
*The code for empty slot is ''O''
Rated Output Wattage: 1200W
Slots: 6
Rated Output Voltage: 3.3V,5V,7.5V,12V,15V,24V,36V,48V,24V/24V
Features of AME1200F
• Flexible modular system architecture provides various output configuration• Low profile(41mm, 1.61inch=meet to 1U height)
• Universal input (85-264VAC)
• For medical electrical equipment
ˇˇ(ANSI/AAMI ES60601-1, EN60601-1 3rd, IEC60601-1-2 4th Ed.)
• Medical Isolation Grade 2MOPP
• With AUX output 5V 1A
• Global Inhibit, Remote ON/OFF control, alarm
• Output connector is available (Option: -J2Ł©
• Monitoring function and some parameter changes by communication are available(Option: -I3, -I).
Ordering Information and Options
The AME series has Order Name which is used for the ordering aside from Model Name.Please refer to Configuration-Model Name Construction in Instruction manual for Order Name.
Order Name is required to create by the above menu.
ˇöModel Name
AM(1Ł©ˇˇˇő(2Ł©ˇˇ-ˇˇˇő(3Ł©ˇˇˇő(4Ł©ˇˇˇő(5Ł©ˇˇˇő(6Ł©ˇˇˇő(7Ł©ˇˇˇő(8Ł©ˇˇ-ˇˇˇőˇő(9Ł©ˇőˇő(10ˇˇ-ˇˇˇő(11)ˇˇ
(1Ł© Abbreviation for series name of AME series(2Ł© Abbreviation for output power of AME series
12: AME1200F(AM12Ł©
(3Ł© Slot 6 Output module
(4Ł© Slot 5 Output module
(5Ł© Slot 4 Output module
(6Ł© Slot 3 Output module
(7Ł© Slot 2 Output module
(8Ł© Slot 1 Output module
(9Ł© Parallel code
(10Ł©Series code
(11) Option
A: 12V/0.1A AUX instead of 5V1A
R: Reversed logic remote on/off
J2: Output connector type
J3: CN1/CN2/CN3 Molex connectors
C: with Coating
F3: Revers air exhaust type
G: Low leakage current
I3: with Extented-UART interface
I: with PMBus interface
Refer to instruction manual 6.1
*The number of slot is different depending on the model.
*The code for empty slot is ''O''
Specification
Input Module
Contents | Specifications | ||
---|---|---|---|
Input Voltage | 85 - 264VAC 1Φ * | ||
Output | Number of Slot | 6 | |
Total Output power | AC90 - 150V | 1000W | |
AC170 - 264V | 1200W | ||
Operating Temperature/Humidity | -20 to +70ˇć, 20 - 90%RH (Non condensingŁ© * | ||
Safety And Noise Regulations | Agency Approvals (At only AC input) |
UL62368-1, C-UL Ł¨CSA62368-1Ł©, EN62368-1, ANSI/AAMI ES60601-1, EN60601-1 3rd , Complies with IEC60601-1-2 4th Ed. |
|
Conducted Noise | Complies with FCC-B, VCCI-B, CISPR11-B,CISPR32-B, EN55011-B, EN55032-B | ||
High Attenuation | Complies with IEC61000-3-2 * | ||
Others | Dimensions (WxHxD) | 127×41×257mm | |
Weight | 1.8kg max | ||
Cooling Method | Forced cooling (internal fanŁ© | ||
Warranty Period | 5-year (Refer to Instruction ManualsŁ© |
Output Module
120W Suitable Single Output
Contents | Specifications | ||||||||
---|---|---|---|---|---|---|---|---|---|
Module Code | J | A | K | B | L | C | M | D | |
Number of Slots Used | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | |
Wattage | 50.16W | 60W | 90W | 102W | 120W | 120W | 122.4W | 120W | |
Voltage/Current |
3.3V 15.2A |
5V 12A |
7.5V 12A |
12V 8.5A |
15V 8A |
24V 5A |
36V 3.4A |
48V 2.5A |
|
Adjustable Voltage Range |
2.64 to 3.96V |
4.0 to 6.0V |
6.0 to 9.0V |
9.6 to 14.4V |
12.0 to 18.0V |
19.2 to 28.8V |
28.8 to 43.2V |
38.4 to 57.6V |
|
Overcurrent Protection |
Works over 105% of rated current. Automatic recovery. Hiccup mode.
|
||||||||
Overvoltage Protection |
4.2 to 5.6V |
6.5 to 7.8V |
9.4 to 11.6V |
15.0 to 18.6V |
18.8 to 23.2V |
30.0 to 37.2V |
45.0 to 55.8V |
60.0 to 74.4V |
|
Protection Circuit And Others |
Remote ON/OFF(RC), Alarm(LV), DC_OK(LED:Blue)
|
240W Suitable Single Output
Contents | Specifications | ||||||||
---|---|---|---|---|---|---|---|---|---|
Module Code | E4 | E | F4 | F | G4 | G | H4 | H | |
Number of Slots Used | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | |
Wattage | 105.6W | 160W | 150W | 240W |
150W (Peak 225W) |
240W (Peak 360W) |
180W (Peak 270W) |
240W (Peak 360W) |
|
Voltage/Current |
3.3V 32A |
5V 32A |
7.5V 20A |
12V 20A |
15V 10A (Peak 15A) |
24V 10A (Peak 15A) |
36V 5A (Peak 7.5A) |
48V 5A (Peak 7.5A) |
|
Adjustable Voltage Range |
3.0 to 6.0V |
3.0 to 6.0V |
7.2 to 14.4V |
7.2 to 14.4V |
14.4 to 28.8V |
14.4 to 28.8V |
28.8 to 57.6V |
28.8 to 57.6V |
|
Overcurrent Protection |
Works over 105% min of rated current or 101% min of peak current. Automatic recovery. Hiccup mode.
|
||||||||
Overvoltage Protection |
Vo + 1.0 to 1.5V |
Vo + 1.0 to 1.5V |
Vo + 1.2 to 2.4V |
Vo + 1.2 to 2.4V |
Vo + 2.4 to 4.8V |
Vo + 2.4 to 4.8V |
Vo + 4.8 to 7.2V |
Vo + 4.8 to 7.2V |
|
Protection Circuit And Others |
Remote ON/OFF(RC), Alarm(LV), Remote sensing (+S/-S),
Output voltage adjustment (VTRM), Constant output current adjustment (ITRM), DC_OK(LED:Blue) |
150W Isolated dual output
Contents | Specifications | |
---|---|---|
Module Code | R | |
Number of Slots Used | 1 | |
Wattage | 72W | 72W |
Voltage/Current | 24V 3A | 24V 3A |
Adjustable Voltage Range | 5.0 to 25.2V | 5.0 to 25.2V |
Overcurrent Protection |
Works over 105% of rated current. Automatic recovery.
|
|
Overvoltage Protection | 30.0 to 37.2V | 30.0 to 37.2V |
Protection Circuit And Others |
Remote ON/OFF(RC), Alarm(LV), DC_OK(LED:Blue)
|