TSURAGA MODEL 1913, 1914 Bargraph Meter Tsuruga
Quantity
Add Quotation


  • ¡öClear bar graph display by adopting a custom LED
  • ¡öHigh Accuracy and high reliability because of LSI adoption
  • ¡öSetting and change of setting value are possible from the front panel.
  •  
  • Model Designation
  • 191 ¡õ - ¡õ - ¡õ
      A   B   C
    A Setting Points
    Code Settings
    3 2 set points (H/L)
    4 4 set points (HH/H/L/LL)
    B Input
    Code Input
    1 DC 0-1 mA
    2 DC 4-20 mA
    3 DC 0-1 V
    4 DC 1-5 V
    5 DC 0-5 V
    0 Other than those above *
    *:
    Input Voltage less than DC 10 V
    Input Current less than DC 50 mA
    C Power Supply
    Code Power Voltage
    A AC 85-264 V
    7 DC 5 V *
    9 DC 24 V
    *:
    Terminals between power supply and input are non-insulated..

    Specifications

    Models 1913 1914
    Display LED (Color: Red)
    Bar dots 101
    Scale length 100 mm¡¡(1.5 mm width)
    Accuracy ±(1% of FS + 1 digit)
    Response time 0.5s
    Scale plate Black Aluminum(White scale & white characters)
    H/L settings H / L (2 points) HH / H / L / LL (4 points)
    Output signal Contact output
    Setting range H£º(set value of L + 1%) to 100%
    L£º(set value of H - 1%) to 0%
    HH £º(set value of H + 1%)to 100%
    H £º(set value of HH - 1%)to(set value of L +1%)
    L £º(set value of H - 1%)to(set value of LL + 1%)
    LL £º(set value of L - 1%)to 0%
    Relay output H : 1 transfer
    L : 1 transfer
    H / L : Contact on each 1a
    HH / LL : 1 transfer *
    Contact capacity AC125V¡¡0.5A (Resistance load)
    Insulation resistance Between all terminals to outer case¡¡DC 500 V, More than 10 MΩ
    Withstanding voltage
    Between input terminals and outer case AC 1500 V 1min.
    Between Input and Power Supply terminals AC 1500 V 1min.(AC)
    Between Input and Power Supply terminals AC 500 V 1min.(DC 24 V)
    Between relay contacts and Other Circuits AC 1000 V 1min.
    Power supply AC 85-264 V¡¡50/60 Hz
    DC 24 V ± 15%
    DC 5 V ± 5%
    Power consumption 7 VA(AC 85-264 V)
    4 W(DC 24 V)
    2 W(DC 5 V)
    Operating temperature 0 to 45°C
    Storage temperature -20 to 70°C
    Weight Applox. 400 g Applox. 420 g

    *HH and H£¯LL and L£ºCommon terminals are common to each other

    Input Specifications

    Code Input Signal Input Impedance
    1 DC 0-1 mA 200 Ω
    2 DC 4-20 mA 10 Ω
    3 DC 0-1 V More than 100 kΩ
    4 DC 1-5 V More than 250 kΩ
    5 DC 0-5 V
    No. 1 2 3 4 5 6 7 8 9 10 11 12
    Max. value 1 1.2 1.5 2 2.5 3 4 5 6 7.5 8 9
    Division No. 50 24 30 40 50 30 40 50 30 37.5 40 45
     

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  

You have 0 items in you cart. Would you like to checkout now?
0 items
Switch to Mobile Version