- Allen-Bradley
- ASHCROFT
- New & Featured Products - HPS high-purity pressure gauge with Reed Switch
- New & Featured Products - S1 Pressure Transducer
- New & Featured Products - ZT12 High Purity Pressure Transmitter
- New & Featured Products - ZX12 High Purity Pressure Transmitter
- Pressure Instruments - Accessories
- Pressure Instruments - Diaphragm Seals-Isolators
- Pressure Instruments - Pressure Gauges
- Pressure Instruments - Pressure Sensors (Transducers/Transmitters)
- Pressure Instruments - Pressure Switches
- Pressure Instruments - SMART Transmitter Assemblies
- Temperature Instruments - MultiPoint Temperature Sensors
- Temperature Instruments - OEM Temperature Sensors
- Temperature Instruments - RTDs
- Temperature Instruments - Temperature Switches
- Temperature Instruments - Thermocouples
- Temperature Instruments - Thermometers
- Temperature Instruments - Thermowells
- Test Instruments - Calibrators
- Test Instruments - Hand Pumps-Controllers
- Test Instruments - Hydraulic Testers
- Test Instruments - Test Gauges
- Cosel
- Euromag
- eYc
- Finetek
- Huba Control
- Koyo
- Maxwell
- MEKKO
- Prokits
- 3C Product Repair Tools
- Aid Tools
- Alignment Tools & Screwdrivers
- Ceramic Driver
- Crimpers
- Cutter
- Drill Bits
- Driver Set
- Electrical Pliers
- Fiber Optics
- Hex Key Wrenches
- Hex Nut Drivers
- Knives & Scissors
- Miscellaneous
- Plier
- Power Tools
- Precision Tweezers
- Punch Down Tools
- Socket Wrenches
- Soldering & Desoldering
- Storage Box
- Strippers
- Test Instruments
- VDE Insulation Tools
- Setra
- Siemens
- SIMEX
- Sondar
- SURE INSTRUMENTS
- Suto
- Tsuruga
- VAISALA
- VE-PURE
- WELTEM
- Winters Instruments
TECH IMPRO AUTOMATION SOLUTION SDN BHD
7263, 1st Floor, Lorong Chempa, 12200 Butterworth, Penang, Malaysia.
+6012-466 1514
TSURUGA MODEL 442C
Previous | 2 / 4 | Next |
Intergrating Printer
- ¡ö Automatically prints the hourly report, daily report, monthly report and operating time at the specified time.
- ¡ö Integrated value, operating time etc. can be manually printed at suitable time.
- ¡ö Monthly report of the previous year can be printed.
- ¡ö Currently measured value can be obtained from output of analog signals.
- ¡ö 2 points of integrated input and 2 points of operation input are available on standard equipment.
- ¡ö Suitable for the flow rate integration, co-generation power accumulating records.
- Model Designation
-
442C - ¡õ - ¡õ ¢Ù ¢Ú General Specifications
Integrated input Input 2CH (no isolation btw. CH)
Dry contact or Open collector (NPN)
Contact rate: 5 V DC, 10 mACount range 0 to 99999999¡¡£¨Start from 0 when an integration value exceed 99999999£© Input frequency HF: 1250 Hz Max. Pulse width more than 400 µs
LF: 100 Hz Max. Pulse width more than 5 msPulse parameter ×0.001, ×0.005, ×0.01, ×0.05, ×0.1, ×0.5, ×1, ×5, ×10, ×50, ×100 Computation A+B, A-B for Integrated input A, B Reset RESET or Start printing (Hourly report, Daily report, Monthly report, and Monthly report memory). Work time Input 2 points.
Dry contact or Open collector (NPN)
Contact rate: 5 V DC. 10 mACount range 0 to 536870911s (approx. 17 years) Reset RESET or Start printing (Hourly report, Daily report, Monthly report, and Monthly report memory). Indication Integrated 0 to (99)999999 Last 6 digits, with Zero suppress. When the lower 6 digits exceed 999999, the decimal point at 106 is flashing. Cycle: 100ms
Integration A, Integration B, Integration computation (A+B, A-B), Switching indication (Date - Integration).Clock Year/Month/Date or Hour/Minute/Second Control Signal Input Output Print Style Thermal line dot. Character Alphabet, Numbers, Katakana, Symbols, etc. Dot 16 × 16£¨2 mm × 2 mm£© Digit 24 digits, Max. Printing speed Approx. 22.5 mm/s, 6 lines/s, Max. Note) Printing rate: Less than 16%. Printing width 46 mm Life time At 25 °C Paper Calendar Clock Accuracy: ±3s, per day. (at 25°C)
A leap year adjustment: Automatic adjustment till 2099.Power failure measure Set value, Integration value, Work time, Monthly reports are memorized by Non-volatilization memory. Power Supply AC 100 to 240 V 50/60 Hz ¡¡DC 24 V ± 10% Power Range AC 90 to 250 V ¡¡DC 21.6 to 26.4 V Power Consumption AC 100 V£º16 VA, AC 200 V: 20 VA
DC 24 V: 500 mAOperating temperature & humidity 0 to 50°C, less than 85% RH £¨no condensation£© Storage Temperature -20 to 60°C Weight Approx. 700 g Installation Panel mounting Withstand Voltage Insulation Resistance Option Analog output¡¡DC 1 to 5 V or DC 4 to 20 mA - Printing example