Thermocouple, Resistance Themometer

  • ¡ö Multi input having capability of dealing with 9 types of temperature sensors.
  • ¡ö Large display with 192×96 mm DIN size.
  • ¡ö 51mm clear and bright LED.
  •  
  • Model Designation
  • 3155C - ¡õ - ¡õ
        ¢Ù   ¢Ú

    ¢ÙInput

    Thermocouple
    Code Type Measuring Range Display Range Accuracy
    TC R 100 to 1700°C -50 to 1750°C ±(0.3% of rdg + 1°C)
    K -100 to 1300°C -199 to 1350°C
    E -130 to 1000°C -199 to 1050°C
    J -140 to 1200°C -199 to 1250°C
    T -199 to 400°C -199 to 420°C
    B 600 to 1800°C -20 to 1810°C
    N -100 to 1300°C -199 to 1350°C
       * Accuracy:
    Defined at 23 ± 5°C, 45 to 75% RH.
         Temperature coefficient:
    ±300 ppm/°C (Temp. range: 0 to 50°C)
    Calibrated by standard thermal power mV input in compliance with JIS C 1602.
         Standard contact compensation:
    Defined at ±1°C (Temp. range: 0 to 50°C)
    Resistance Thermometer
    Code Type Measuring Range Display Range Accuracy
    PT Pt100Ω -199.9 to 600.0°C -199.9 to 650.0°C ±(0.2% of rdg + 0.3°C)
    JP100Ω
       * Accuracy:
    Defined at 23 ± 5°C, 45 to 75% RH.
         Temperature coefficient:
    ±200 ppm/°C (Temp. range: 0 to 50°C)
    Calibrated by resistance of standard resistive elements in compliance with JIS C 1604.

    ¢Ú Power Supply

    Code Tolerance of source voltage
    3 AC 90 to 132 V
    5 AC 180 to 250 V

    General Specifications

    Display Red LED, character height 51 mm, with zero-suppress function.
    Over-range display When exceeding the display range, flashes with minimum or maximum value.
    Open circuit of input Thermocouple: flashs with min. value of display range
    Resistance Thermometer: flashs with max. value of display range
    Resolution Thermocouple: 1°C
    Resistance Thermometer: 0.1°C
    External resistance Thermocouple: Less than 500 Ω
    Resistance thermometer: Less than 5 Ω/lead wire
    Overload DC ±10 V
    Sampling rate Approx. 2.5 times/sec.
    Input configuration Single ended, floating input
    A/D conversion ¨S-∑ conversion system
    Noise rejection Normal mode (NMR) More than 50 dB
    Common mode (CMR) More than 110 dB
    Power source line mixing noise 1000 V
    Hold function Holds measurement data. (Not isolated from input)
    Withstand voltage Between input terminal and external case: AC 1500 V for 1min.
    Between power supply terminals and external case: AC 1500 V for 1min.
    Between power supply terminals and input terminals: AC 1500 V for 1min.
    Insulation resistance DC 500 V  More than 100 MΩ
    Operating temperature 0 to 50°C
    Weight Approx. 1.3 kg