TSURUGA MODEL 415M Panel Meter Digital/Printer Tsuruga
Quantity
Add Quotation


Digital Thermometer

  • ¡ö Front panel including all switches are water proof (IP65 level)
  • ¡ö DIN 72×36 mm compact size.
  • ¡ö Compatible with various thermal sensors.
  •  
  • Model Designation
  • 415M - ¡õ - ¡õ - ¡õ - ¡õ
        ¢Ù   ¢Ú   ¢Û   ¢Ü

    ¢ÙInput

    Thermocouple
    Code Type *1 Measuring Range Display Range Accuracy *2
    T C R 100 to 1700°C -50 to 1750°C ±(0.3% of rdg + 1°C)
    K -100 to 1300°C -199 to 1350°C
    E -130 to 1000°C -199 to 1050°C
    J -140 to 1200°C -199 to 1250°C
    T -199 to 400°C -199 to 420°C
    B 600 to 1800°C -20 to 1810°C
    N -100 to 1300°C -199 to 1350°C
    *1 There will be °C display of K type T/C during shipment.
    *2 Accuracy : Defined in the measuring range, at 23 ± 5°C, 45 to 75% RH.
    Temperature coefficient : ±300 ppm/°C (operating temp.: 0 to 50°C)
    Cold junction compensation : ±1°C (operating temp.: 0 to 50°C)
    Calibration is made with standard thermo-electricity input (mV) in accordance with JIS C-1602.
    Resistance Thermometer
    Code Type *3 Measuring Range Display Range Accuracy *4
    PT Pt100Ω -199.9 to 600.0°C -199.9 to 650.0°C ±(0.2% ofrdg + 0.3°C)
    JPt100Ω
    *3 There will be Pt100Ω and °C setting display during shipment.
    *4 Accuracy : Defined in the measuring range, at 23 ± 5°C, 45 to 75% RH.
    Temperature coefficient : ±200 ppm/°C (operating temp.: 0 to 50°C)
    Calibration is made with standard resistance values in accordance with JIS C-1604.

    ¢Ú Power Supply

    Code Tolerance of source voltage
    A AC 90 to 250 V
    B DC 9 to 32 V

    ¢ÛData Output / Comparative Output

    Code Specifications Output Impedance Allowable Load Resistance
    Blank For display only
    03 Analog output ¡¡DC 0 to 1 V Less than 0.1 Ω More than 1 kΩ
    04 Analog output ¡¡DC 0 to 5 V Less than 0.1 Ω More than 5 kΩ
    05 Analog output ¡¡DC 0 to 10 V Less than 0.1 Ω More than 10 kΩ
    09 Analog output ¡¡DC 1 to 5 V Less than 0.1 Ω More than 5 kΩ
    23 Analog output ¡¡DC 0 to 1 mA More than 5 MΩ 0 to 5 kΩ
    29 Analog output ¡¡DC 4 to 20 mA More than 5 MΩ 0 to 600 Ω
    BP BCD output £¨TTL level: positive logic£©
    BN BCD output £¨TTL level: negative logic£©
    DN BCD output £¨Transistor output sink type£©
    RY Dual setting comparator £¨Relay contact output£©
    TN Dual setting comparator £¨Open collector output NPN£©
    TP Dual setting comparator £¨Open collector output PNP£©

    ¢ÜDisplay Color

    Code Description
    Blank Red LED
    G Green LED

    General Specifications

    Display Red or green LED (character height 15 mm) with zero-suppress function.
    Mode change-over 1 digit, red or green LED (character height: 8 mm)
    Over-range display When exceeded the displayable range, the minimum or maximum value of the displayable range flashes.
    Open circuit of input Thermocouple input: Flashs with the minimum value of the display range.
    Resistance thermo bulb input: Flashs with the maximum value of the display range.
    Resolution Thermocouple: 1°C
    Resistance Thermometer: 0.1°C
    External resistance Thermocouple input: Less than 500 Ω
    Resistance thermo bulb input: Less than 5 Ω/lead wire
    Overload DC ±10 V
    Sampling rate Approx. 2.5 times/sec.
    Input configuration Single ended, floating input
    A/D conversion ¨S-∑ conversion system¡¡¡¡
    Noise rejection Normal mode (NMR) More than 50 dB
    Common mode (CMR) More than 110 dB
    Power source line mixing noise 1000 V
    Hold function Holds measured data, peak/bottom memory value and data output (option).
    (Not isolated from the input)
    Peak/bottom memory function Display of maximum or minimum value is selectable with the front panel switch.
    Withstand voltage Between input terminals and each output COM: AC 500 V for 1min.
    Between input terminals and relay output: AC 1000 V for 1min.
    Between input/output terminals and power source terminals: AC 1500 V for 1min.
    (For DC power source: 1000 V AC for 1min.)
    Between power source terminals and external case: AC 1500 V for 1min.
    Insulation resistance DC 500 V, More than 100 MΩ
    Operating temperature 0 to 50°C
    Protection degree Operation section on the front IP65, Rear case IP20, Terminals section IP00
    Weight Approx. 200 g