TECH IMPRO AUTOMATION SOLUTION SDN BHD
7263, 1st Floor, Lorong Chempa, 12200 Butterworth, Penang, Malaysia.
+6012-466 1514

TSURUGA MODEL 3126

Previous 9 / 25 Next

TSURUGA MODEL 3126 Panel Meter Digital/Printer Tsuruga
Quantity
Add Quotation


Thermocouple, Resistance Thermocouple

  • ¡ö DIN size 24×48 mm Thermometer.
  • ¡ö Available with thermocouple input, Resistance thermometer.
  • ¡ö Available with analog output too.
  •  
  • Model Designal
  • 3126 - ¡õ - ¡õ - ¡õ
        ¢Ù   ¢Ú   ¢Û

    ¢ÙMeasuring Input

    Thermocouple (T/C)
    Code Type of T/C Measuring Range Display Range Accuracy *1
    01 R 100 to 1700°C -50 to 1750°C ±(0.5% of rdg + 1°C)
    02 K -100 to 1300°C -100 to 1350°C
    04 J 0 to 1200°C -50 to 1250°C
    05 T -100 to 400°C £­150 to 420°C
    *1 Accuracy:
    Defined at 23 ± 5°C, 45 to 75% RH.
        Temperature coefficient:
    ±300 ppm/°C (Temp. range: 0 to 50°C)
    Calibrated by standard thermal power mV input in compliance with JIS C 1602.
    Standard contact compensation:
    Defined at ±2°C (Temp. range: 0 to 50°C)
    Resistance Thermometer
    Code Type of sensor Measuring Range Display Range Accuracy¡¡*2
    12 Pt100Ω -199.9 to 199.9°C -199.9 to 199.9°C ±(0.2% of rdg + 0.3°C)
    11 -199 to 600°C -199 to 650°C ±(0.4% of rdg + 1°C)
    *2  Accuracyy:
       Defined at 23 ± 5°C, 45 to 75% RH.
         Temperature coefficient:
    ±200 ppm/°C (Temp. range: 0 to 50°C)
    Calibrated by resistance of standard resistive elements in compliance with JIS C 1604.

    ¢ÚDisplay Color

    Code Description
    Blank Red LED
    £Ç Green LED

    ¢ÛOption

    Code Input
    Blank null
    A01 analog output

    General Specifications

    Display Red or green LED (character height 10 mm) with zero-suppress function.
    Over-range indication When exceeding the display range, flashes with minimum or maximum value.
    Open circuit of input Thermocouple: flashing with minimum value
    Resistance thermometer: flashing with maximum value
    Resolution Thermocouple: 1°C
    Resistance thermometer: 1°C or 0.1°C
    External resistance Thermocouple: Less than 500 Ω
    Resistance thermometer: Less than 5 Ω/lead wire
    Overload DC ±3.3 V
    Sampling rate 2.5 times/s
    Input configuration Single ended, floating input
    A/D conversion ¨S£­Σ conversion system
    Noise rejection Normal mode £¨NMR)  More than 50dB
    Hold function Holds measured data and analog output (option). (Not isolated from the input)
    °F indication °F £½ °C × 9 / 5 + 32.0
    Withstand voltage Between input terminals and external case: AC 500 V each for 1min.
    Between power supply terminals and external case: AC 500 V each for 1min.
    Between power supply terminals and input terminals: AC 500 V each for 1min.
    Insulation resistance DC 500 V  More than 100 MΩ
    Power supply DC 12 to 24 V
    Tolerance of source voltage DC 9 to 32 V
    Power consumption DC 12 V … 60 mA
    DC 24 V … 40 mA
    Operating temperature 0 to 50°C
    Storage temperature -20 to 70°C
    Weight Approx. 55 g
    Mounting Method Snap-in type

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  

You have 0 items in you cart. Would you like to checkout now?
0 items
Switch to Mobile Version