- Allen-Bradley
- ASHCROFT
- New & Featured Products - HPS high-purity pressure gauge with Reed Switch
- New & Featured Products - S1 Pressure Transducer
- New & Featured Products - ZT12 High Purity Pressure Transmitter
- New & Featured Products - ZX12 High Purity Pressure Transmitter
- Pressure Instruments - Accessories
- Pressure Instruments - Diaphragm Seals-Isolators
- Pressure Instruments - Pressure Gauges
- Pressure Instruments - Pressure Sensors (Transducers/Transmitters)
- Pressure Instruments - Pressure Switches
- Pressure Instruments - SMART Transmitter Assemblies
- Temperature Instruments - MultiPoint Temperature Sensors
- Temperature Instruments - OEM Temperature Sensors
- Temperature Instruments - RTDs
- Temperature Instruments - Temperature Switches
- Temperature Instruments - Thermocouples
- Temperature Instruments - Thermometers
- Temperature Instruments - Thermowells
- Test Instruments - Calibrators
- Test Instruments - Hand Pumps-Controllers
- Test Instruments - Hydraulic Testers
- Test Instruments - Test Gauges
- Cosel
- Euromag
- eYc
- Finetek
- Huba Control
- Koyo
- Maxwell
- MEKKO
- Prokits
- 3C Product Repair Tools
- Aid Tools
- Alignment Tools & Screwdrivers
- Ceramic Driver
- Crimpers
- Cutter
- Drill Bits
- Driver Set
- Electrical Pliers
- Fiber Optics
- Hex Key Wrenches
- Hex Nut Drivers
- Knives & Scissors
- Miscellaneous
- Plier
- Power Tools
- Precision Tweezers
- Punch Down Tools
- Socket Wrenches
- Soldering & Desoldering
- Storage Box
- Strippers
- Test Instruments
- VDE Insulation Tools
- Setra
- Siemens
- SIMEX
- Sondar
- SURE INSTRUMENTS
- Suto
- Tsuruga
- VAISALA
- VE-PURE
- WELTEM
- Winters Instruments
TECH IMPRO AUTOMATION SOLUTION SDN BHD
7263, 1st Floor, Lorong Chempa, 12200 Butterworth, Penang, Malaysia.
+6012-466 1514
TSURUGA MODEL 3153B
Previous | 10 / 25 | Next |
DC Voltmeter/ Ammeter
- ¡ö 45 mm character size clear bright large LED display.
- ¡ö Equipped with scaling function.
- ¡ö Available with average calculation, display hold, peak/bottom display function.
- ¡ö AC power supply 100 to 240 V.
- Model Designation
-
3153B - ¡õ - A - ¡õ ¢Ù ¢Ú ¢Û ¢ÙMeasuring Input
Code Measuring Range Input Resistance Accuracy * Overload 02 ±99.99 mV 100 MΩ ±(0.05% of rdg + 1 digit) DC ±250 V 03 ±999.9 mV 10 MΩ ±(0.05% of rdg + 1 digit) DC ±250 V 04 ±9.999 V 10 MΩ ±(0.1% of rdg + 1 digit) DC ±250 V 05 ±99.99 V 10 MΩ ±(0.1% of rdg + 1 digit) DC ±500 V 09 1 to 5 V 1 MΩ ±(0.1% of rdg + 1 digit) DC ±250 V 13 ±999.9 µA 100 Ω ±(0.1% of rdg + 1 digit) DC ±50 mA 14 ±9.999 mA 10 Ω ±(0.1% of rdg + 1 digit) DC ±150 mA 15 ±99.99 mA 1 Ω ±(0.1% of rdg + 1 digit) DC ±500 mA 16 ±999.9 mA 0.1 Ω ±(0.1% of rdg + 1 digit£© DC ±2 A 19 4 to 20 mA 12.5 Ω ±(0.1% of rdg + 1 digit£© DC ±150 mA General Specifications
Display Red or green LED, character height 45 mm, with zero-suppress function. Display scaling Full scale display: -9999 to 9999
Offset display: -9999 to 9999Offset fixing function The display for the value less than the offset value can be set to display the offset value. Decimal point Arbitrarily settable from the terminal blocks Over-range display When exceeded 100% or 130%, indicated with
When exceeded -100% or -130%, indicated with .Display cycle 67ms, 400ms, 1s, 2s, 3s, 4s, 5s Selection of setting available Average calculation Divisional averaging or moving average, and the numbers of samples for averaging can be selected.
OFF: No moving averaging
ON: Divisional averaging
Numbers of sample for averaging, 2, 4, 8, 16, 32Hold function Holds measurement data (No isolation and measurement input) Peak / Bottom change-over Function of the terminal block P/B can be changed to maximum or minimum value display. 100 digit turn out The display of 100 digit is compulsorily turn out. Power supply AC 100 to 240 V, 50/60 Hz Tolerance of source voltage AC 90 to 250 V Power consumption AC 100 V … Approx. 4 VA
AC 200 V … Approx. 5 VAOperating temperature 0 to 50°C Operating humidity 35 to 85% RH¡¡£¨No condensation£© Storage temperature -20 to 70°C Insulation resistance DC 500 V¡¡ More than 50 MΩ Withstand voltage Between input terminal and external case: AC 1500 V for 1min.
Between power supply terminals and external case: AC 1500 V for 1min.
Between power supply terminals and input terminals: AC 1500 V for 1min.Weight Approx. 900 g Unit Indication Designated character is adhered at the right bottom of the front mask.
(It has to be designated at the time of ordering.)Protection Degree Front side IP40, back side IP20