Integrating Digital Panel meter (Pulse Input)

  • ¡ö Instantaneous measurement value like flow rate and totalized value can be displayed.
  • ¡ö LCD display with large and clear characters.
  • ¡ö Power supply can be selectable:
    Free AC voltage or DC 24 V or DC 110 V.
  • ¡ö Protection rank of front panel is IP65
  •  
  • Model Designation
  • 471B - ¡õ - ¡õ - ¡õ - ¡õ - ¡õ
        ¢Ù   ¢Ú   ¢Û   ¢Ü   ¢Ý

    ¢Ù Power supply

    Code Power Supply Voltage
    A AC 100 to 240 V
    9 DC 24 V
    C DC 110 V

    ¢Ú Sensor power supply

    Code Output specification
    X None
    3 DC 12 V ± 5 % 150 mA
    5 DC 24 V ± 5 % 50 mA

    ¢Û Comparative output

    Code Output
    X None
    2 With comparative output

    ¢Ü Analog output

    Code description Allowable load resistance
    X No output ---
    04 DC 0 to 5 V More than 1 kΩ
    05 DC 0 to 10 V More than 1 kΩ
    09 DC 1 to 5 V More than 1 kΩ
    29 DC 4 to 20 mA Less than 510 Ω

    ¢Ý Digital output

    Code Optional Output
    X No output
    DN BCD (Open collector/NPN)
    E0 RS-232C
    E1 RS-485

    General Specifications

    Measurement input Non-voltage contact, Open collector (NPN /PNP)
    Voltage pulse, DC 2 wire-system
    Instantaneous value
    Display of instantaneous value Display 1 or 2: 0 to 999999
    Decimal point can be set in setting mode.
    With zero suppress, Over display functions
    Display cycle 100 ms, 1 s or 5 s
    Pulse conversion 1 x 10-6 to 1000
    Unit of time hr, min, sec
    Display accuracy ± (0.05 % + 1 digit) at 23 ¡æ ± 5 ¡æ  45 to 75 %RH
    Temperature coefficient ± 200 ppm/¡æ
    Totalized value
    Display of totalized value Display 1: 0 to 999999 (lower 6 digits) with Over display
    Display 2: 0 to 99999999
    100 ms
    Pulse coefficient 1 x 10-9 to 9999
    Initial value of totalization 0 to 999999
    Display cycle 100 ms
    Input frequency HF range: 0.01 Hz to 1 kHz   Pulse width 50 μs
    MF range: 0.01 Hz to 100 Hz  Pulse width 5 ms
    LF range: 0.01 Hz to 20 Hz   Pulse  width 25 ms
    Display Display 1: Red or Green LCD     Character height: 15.2 mm
    Display 2: White LCD     Character height: 7.6 mm
    With no display function
    Cut-off time 0.1 to 199.9 s
    Synchronized totalized pulse output (P.O.) As totalized value is counted up¡¢the pulse output is obtained.
    Output signal: Open collector output(NPN)  DC 30 V 200 mA
    Pulse width: 100 ms, 5 ms, 50 μs
    Pause/Latch [Pause]
    Display of instantaneous and totalized values, data output are retained. Count of totalizing is stopped.
    [Latch]
    Display and data output of instantaneous and totalized values, and output are retained. Count of totalization and P.O output are continued.
    Reset Reset of totalization
    Power failure compensation Measurement data is held in nonvolatile memory.
    Date is retained for approx. 10 years.
    No counting during electricity failure.
    Supply voltage AC 100 to 240 V, DC 24 V or DC 110 V
    Voltage tolerance of power supply AC 90 to 250 V, DC 24 V ± 10 %, DC 100 to 170 V
    Power consumption AC 100 V: Approx. 11 VA, AC 220 V: Approx. 15 VA
    DC 24 V: Approx. 250 mA, DC 110 V: Approx.50 mA
    Operating ambient environment 0 to 50 ¡æ
    Storage temperature -20 to 65 ¡æ
    Outer dimension 90 (W) x 48 (H) x 133.3 (D) mm
    Weight Approx. 300 g
    Protection Front operation unit: IP65
    Rear case: IP20
    Terminals: IP00
    Installation Using special bracket