- Allen-Bradley
- ASHCROFT
- New & Featured Products - HPS high-purity pressure gauge with Reed Switch
- New & Featured Products - S1 Pressure Transducer
- New & Featured Products - ZT12 High Purity Pressure Transmitter
- New & Featured Products - ZX12 High Purity Pressure Transmitter
- Pressure Instruments - Accessories
- Pressure Instruments - Diaphragm Seals-Isolators
- Pressure Instruments - Pressure Gauges
- Pressure Instruments - Pressure Sensors (Transducers/Transmitters)
- Pressure Instruments - Pressure Switches
- Pressure Instruments - SMART Transmitter Assemblies
- Temperature Instruments - MultiPoint Temperature Sensors
- Temperature Instruments - OEM Temperature Sensors
- Temperature Instruments - RTDs
- Temperature Instruments - Temperature Switches
- Temperature Instruments - Thermocouples
- Temperature Instruments - Thermometers
- Temperature Instruments - Thermowells
- Test Instruments - Calibrators
- Test Instruments - Hand Pumps-Controllers
- Test Instruments - Hydraulic Testers
- Test Instruments - Test Gauges
- Cosel
- Euromag
- eYc
- Finetek
- Huba Control
- Koyo
- Maxwell
- MEKKO
- Prokits
- 3C Product Repair Tools
- Aid Tools
- Alignment Tools & Screwdrivers
- Ceramic Driver
- Crimpers
- Cutter
- Drill Bits
- Driver Set
- Electrical Pliers
- Fiber Optics
- Hex Key Wrenches
- Hex Nut Drivers
- Knives & Scissors
- Miscellaneous
- Plier
- Power Tools
- Precision Tweezers
- Punch Down Tools
- Socket Wrenches
- Soldering & Desoldering
- Storage Box
- Strippers
- Test Instruments
- VDE Insulation Tools
- Setra
- Siemens
- SIMEX
- Sondar
- SURE INSTRUMENTS
- Suto
- Tsuruga
- VAISALA
- VE-PURE
- WELTEM
- Winters Instruments
TECH IMPRO AUTOMATION SOLUTION SDN BHD
7263, 1st Floor, Lorong Chempa, 12200 Butterworth, Penang, Malaysia.
+6012-466 1514
TSURUGA MODEL 419A
Previous | 21 / 25 | Next |
Digital Intergrating Flow rate Meter
- ¡ö DIN 48x48 mm compact size
- ¡ö Dual display of flow rate and totalizer
- ¡ö Pulse output for total and 2 x preset output
- ¡ö Analog input of 419A and pulse input of 419B can be linked in series
- Model Designation
-
419A - ¡õ - ¡õ - ¡õ - ¡õ ¢Ù ¢Ú ¢Û ¢Ü ¢ÙMeasuring input
Code Measuring range Input impedance Over load 02 0 to 99.99 mV More than 1 MΩ DC ±250 V 03 0 to 999.9 mV More than 1 MΩ 04 0 to 5 V More than 1 MΩ 05 0 to 9.999 V More than 1 MΩ 09 1 to 5 V Approx. 1 MΩ 23 0 to 999.9 μA Approx. 100 Ω DC ±50 mA 29 4 to 20 mA Approx. 12 Ω DC ±150 mA 29R 4 to 20 mA Approx. 250 Ω DC ±40 mA ¢ÜAnalog output, RS-485
Code Output specifications Output impedance Tolerable Load resistive Blank - 03 DC 0 to 1 V Approx. 0.1 MΩ More than 200 Ω 04 DC 0 to 5 V More than 1 kΩ 05 DC 0 to 10 V More than 2 kΩ 09 DC 1 to 5 V More than 1 kΩ 29 DC 4 to 20 mA 5 MΩ 0 to 500 Ω E1 RS-485 - Basic Specifications
Flow rate measurement Flow indication 0 to 9999: Red LED, Character 8mm High, with zero-suppress function.
Programmable Decimal point¡¡Over-range displayDisplay blank Changeover to be put on or off. Scaling Full scale and Offset, Programmable 0 – 9999 Resolution 1/9999 Display cycle Selectable from the front key. 100ms, 400ms, 1s, 2s, 5s Moving averaging Selectable from the front key. 1, 2, 3, 4, 8, 16-time Accuracy ±0.2£¥ of SPAN at 23 ± 5°C¡¡ 45 to 75% RH Temperature drift ±200 ppm/°C Input method Single ended, floating A/D conversion V-F conversion method Flow totalize measurement Flow indication 0 to 99999: Green LED, Character 8mm High, with zero-suppress function.
5 or 10 significant digit: Over-range display:
Display blank: Changeover to be put on or off.Integration constant Values integrated in 1 hour at 100% input, programmable from the front key. Primary integrated value from 0 to 99999, programmable from the front key Accuracy ±(0.2%+1digit) of rated value
Rated value: theoretical value when input 100% continuously.Display cycle approx. 100ms Common Specifications Cut off 0 to 10%: Programmable from the front key. Latch / Pause input Latch:
Hold display of instantaneous and integrating flow rate, and data output (except of Simultaneous pulse output). Accumulated integrated count will be operated.
Pause:
Hold display of instantaneous and integrating flow rate, and data output. Accumulated integrated count will be temporarily stopped.
Non-voltage contact or open collector (NPN) DC 5 V, 10 mAReset reset to 0 or primary setting value Backup An EEPROM retains the data of accumulated total flow when the power is interrupted. Keep 10 years. Output relay contact: AC/DC 150 V, 80 mA Noise filter 50 dB at normal mode
110 dB at common mode
1000 V against the power line noisesWithstand Voltage Input terminals - External case: AC 1500 V each for 1min.
Power supply terminals - External case: AC 1500 V each for 1min.
Power supply terminals - Input and Output terminals: AC 1500 V each for 1min.
Input terminals - Output terminals: AC 500 V each for 1min.Insulation Resistance DC 500 V, More than 100 MΩ Power Supply AC 100 to 240 V (50/60 Hz), DC 12 V ±10%, DC 24 V ±10% Allowable power AC 90 to 250 V (50/60 Hz), DC 10.8 to 13.2 V, DC 21.6 to 26.4 V Power Consumption Approx. 7.5 VA at AC 100 V, 10 VA at AC 200 V, 400 mA at DC 12 V, 250 mA at DC 24 V. Operating Temperature 0 to 50°C Storage Temperature -20 to 70°C Weight Approx. 160 g