- Allen-Bradley
- ASHCROFT
- New & Featured Products - HPS high-purity pressure gauge with Reed Switch
- New & Featured Products - S1 Pressure Transducer
- New & Featured Products - ZT12 High Purity Pressure Transmitter
- New & Featured Products - ZX12 High Purity Pressure Transmitter
- Pressure Instruments - Accessories
- Pressure Instruments - Diaphragm Seals-Isolators
- Pressure Instruments - Pressure Gauges
- Pressure Instruments - Pressure Sensors (Transducers/Transmitters)
- Pressure Instruments - Pressure Switches
- Pressure Instruments - SMART Transmitter Assemblies
- Temperature Instruments - MultiPoint Temperature Sensors
- Temperature Instruments - OEM Temperature Sensors
- Temperature Instruments - RTDs
- Temperature Instruments - Temperature Switches
- Temperature Instruments - Thermocouples
- Temperature Instruments - Thermometers
- Temperature Instruments - Thermowells
- Test Instruments - Calibrators
- Test Instruments - Hand Pumps-Controllers
- Test Instruments - Hydraulic Testers
- Test Instruments - Test Gauges
- Cosel
- Euromag
- eYc
- Finetek
- Huba Control
- Koyo
- Maxwell
- MEKKO
- Prokits
- 3C Product Repair Tools
- Aid Tools
- Alignment Tools & Screwdrivers
- Ceramic Driver
- Crimpers
- Cutter
- Drill Bits
- Driver Set
- Electrical Pliers
- Fiber Optics
- Hex Key Wrenches
- Hex Nut Drivers
- Knives & Scissors
- Miscellaneous
- Plier
- Power Tools
- Precision Tweezers
- Punch Down Tools
- Socket Wrenches
- Soldering & Desoldering
- Storage Box
- Strippers
- Test Instruments
- VDE Insulation Tools
- Setra
- Siemens
- SIMEX
- Sondar
- SURE INSTRUMENTS
- Suto
- Tsuruga
- VAISALA
- VE-PURE
- WELTEM
- Winters Instruments
TECH IMPRO AUTOMATION SOLUTION SDN BHD
7263, 1st Floor, Lorong Chempa, 12200 Butterworth, Penang, Malaysia.
+6012-466 1514
TSURUGA MODEL 4258
Previous | 5 / 7 | Next |
- Temperature Measuring Digital Meter Relay
- ¡ö Easy calibration for scaling
- ¡ö Available analog or BCD output
- ¡ö Relay or open collector for comparison output
Model Designation
4258 | - | ¡õ | - | ¡õ | - | ¡õ | - | ¡õ | - | ¡õ |
¢Ù | ¢Ú | ¢Û | ¢Ü | ¢Ý |
¢Ù Power supply voltage
Code | Power source voltage |
---|---|
A | AC 100 to 240 V |
B | DC 12 to 24 V |
¢ÚData output
Code | Data output | Tolerable Load resistive | |
---|---|---|---|
Blank | - | ||
03 | Analog output DC ±1 V | More than 200 Ω | |
04 | Analog output DC ±5 V | More than 1 kΩ | |
05 | Analog output DC ±10 V | More than 2 kΩ | |
09 | Analog output DC 1 to 5 V | More than 1 kΩ | |
23 | Analog output DC ±1 mA | 0 to 10 kΩ | |
24 | Analog output DC ±5 mA | 0 to 2 kΩ | |
29 | Analog output DC 4 to 20 mA | 0 to 600 Ω | |
BP | BCD output (TTL level positive logic) | - | |
BN | BCD output (TTL level negative logic) | - | |
DN | BCD output (transistor output, sink type) | - | |
E1 | RS-485 | - |
Measuring Input
Thermocouple
Sensor | Measuring range | Display range | Accuracy | Over load |
---|---|---|---|---|
R | 100.0 to 1768.0°C | -50.0 to 1800°C | ±(0.3% of rdg + 1°C) | DC ±10 V |
K | -200.0 to 1372.0°C | -270.0 to 1400.0°C | ||
E | -200.0 to 1000.0°C | -270.0 to 1050.0°C | ||
J | -200.0 to 1200.0°C | -210.0 to 1250.0°C | ||
T | -200.0 to 400.0°C | -270.0 to 420.0°C | ||
B | 600.0 to 1800.0°C | -20.0 to 1820.0°C | ||
N | -200.0 to 1300.0°C | -230.0 to 1350.0°C |
Resistance thermobulb
Sensor | Measuring range | Display range | Accuracy | Over load |
---|---|---|---|---|
Pt100Ω | -200.0 to 850.0°C | -200.0 to 870.0°C | ±(0.2% of rdg + 0.3digit) | DC ±10 V |
JPt100Ω | -200.0 to 645.0°C | -200.0 to 660.0°C |
Specification
Display |
Red or Green LED (character height 14.2mm), “-” polarity, with zero-suppress function. During the measuring mode, the display switches from current value to peak memory, bottom memory, display amplitude, and current value. |
---|---|
Sensor selection | Selectable from 9 types of temperature sensor |
Over-range display | Flashing with minimum or maximum value of display range |
Direction of burnout | Flashes at Max. display value. In case of RTD, it is selectable at Max. or Min. display value |
Response | within 1 second or within display cycle, whichever longer |
Resolution | RTD input: 0.1 °C (0.01°C when PT100Ω range 2) |
External resistance |
500Ω Max. for Thermocouple input 5Ω Max. per wire for RTD input |
Sampling rate | Approx. 5 times/s. |
Display cycle | Selectable from 200ms, 400ms, 1s, 2s, 4s, 5s |
Input method | Single ended, floating input |
A/D conversion | ¨S-∑conversion method |
Noise Rejection |
Normal mode (NMR) - More than 50 dB. Common mode (CMR) - More than 110 dB. Noise through power supply line – 1000 V (at AC voltage power supply) |
Comparative digit | Figure: 4-digit, Pole: 1-digit |
Comparative method |
2-isolated contact, programmable of high/low point (for model HI, GO, and LO) CPU comparative judgement method (against display value) |
Judgement | Digital switch setting |
Width of hysteresis | 1 - 999, set the same value for 2-comparative output |
Comparative display | LED display, HI(red), GO(green), and LO(yellow) |
Comparative output |
Relay contact, 1-SPST Normally Open, 125 V 0.5 A AC, 250 V 0.1 A AC (resistive) NPN Open collector, Max. DC 30 V 30 mA, Max. 1.6 V saturation voltage |
Hold | Hold for the measuring data, comparative output, and data output |
Reset | Default the comparative output |
Insulation Resistance | DC 500 V, More than 100 MΩ |
Withstand Voltage |
Input terminals – External case: AC 1500 V each for 1min. Power supply terminals – External case: AC 1500 V each for 1min. Power supply terminals - Input and output terminals: AC 500 V each for 1min. |
Power Supply | AC 100 to 200 V (50/60Hz), DC 12 to 24 V |
Power Consumption | Approx. 5 VA at 100 V AC, 7 VA at 200 V AC, 180 mA at 12 V. 90 mA at 24 V DC. |
Operating Temperature | 0 to 50°C |
Storage Temperature | -20 to 70°C |
Weight | Approx. 450 g |