TECH IMPRO AUTOMATION SOLUTION SDN BHD
7263, 1st Floor, Lorong Chempa, 12200 Butterworth, Penang, Malaysia.
+6012-466 1514

TSURUGA MODEL 4256

Previous 7 / 7 Next

TSURUGA MODEL 4256 Meter Relay Digital/Printer Tsuruga
Quantity
Add Quotation


  • ¡ö Easy calibration for scaling
  • ¡ö Relay or open collector for comparison output
  • ¡ö Peak memory, bottom memory, and display amplitude function
  • ¡ö Free power supply for both AC and DC
  • ¡ö Possibility of stable measurement by Average Calculation Function
  •  
Model Designation
4256 - ¡õ - ¡õ - ¡õ - ¡õ - ¡õ
    ¢Ù   ¢Ú   ¢Û   ¢Ü   ¢Ý

¢Ù Measuring input

DC Input
Code Measuring range Input impedance Accuracy Over load
01 ± 9.999 mV 100 MΩ ± (0.1 % of rdg + 2digit) DC ± 50 V
02 ± 99.99 mV ± (0.05 % of rdg + 1digit) DC ± 250 V
03 ± 999.9 mV
04 ± 9.999 V 10 MΩ
05 ± 99.99 V DC ± 500 V
06 ± 699.9 V ± (0.1 % of rdg + 2digit) DC ± 750 V
09 1 to 5 V 1 MΩ ± (0.05 % of rdg + 2digit) DC ± 250 V
V2 0 to 5 V
11 ± 9.999 μA 10 kΩ ± (0.1 % of rdg + 1digit) DC ± 2 mA
12 ± 99.99 μA 1 kΩ DC ± 20 mA
13 ± 999.9 μA 100 Ω DC ± 50 mA
14 ± 9.999 mA 10 Ω DC ± 150 mA
15 ± 99.99 mA 1 Ω DC ± 500 mA
16 ± 999.9 mA 0.1 Ω ± (0.2 % of rdg + 2digit) DC ± 2 A
19 4 to 20 mA 12.5 Ω ± (0.1 % of rdg + 2digit) DC ± 150 mA
AC Input
Code Measuring range Input impedance Accuracy Over load
22 99.99 mV 10 MΩ ± (0.2 % of rdg + 5digit) AC 10 V
23 999.9 mV AC 100 V
24 9.999 V AC 700 V
25 99.99 V
26 699.9 V ± (0.3 % of rdg + 5digit)
32 99.99 μA 1 kΩ AC 20 mA
33 999.9 μA 100 Ω AC 50 mA
34 9.999 mA 10 Ω AC 150 mA
35 99.99 mA 1 Ω AC 500 mA
36 999.9 mA 0.1 Ω ± (0.5 % of rdg + 10digit) AC 2 A
37 5 A 0.01 Ω AC 10 A

     ¢ÚPower supply voltage

Code Power source voltage
A AC 100 to 240 V
B DC 12 to 24 V

¢ÛAlarm output

Code Specification
Blank Relay contact output
TN Open collector output (NPN)

       ¢ÜComparison System

Code Description
Blank HI,GO,LO *
H HI,GO, 
L GO,LO *

     *Can be changed to HH,H,GO and GO,L,LL
 

¢ÝDisplay color

Code Color
Blank Red LED
G Green LED

¢ÞGO Open collector output

Code Description
Blank Not Provided
A01 Provided
Specification
Display 0 - 9999, red or green LED (character height 15 mm), “-” polarity, with zero-suppress function.
During the measuring mode, the display switches from current value to peak memory, bottom memory,
display amplitude, and current value.
''PM'' illuminates at peak memory display, ''BM'' illuminates at bottom memory display, both ''PM'' and ''BM'' illuminates at display amplitude display.
Decimal point indication Arbitrary position by setting from the front panel and the rear terminals
Over-range display Flashes at 130 %, but blinks ''0000'' when exceeding ''9999''.
Flashes at full scale value when exceeding ''699'' for model 4256-06
Flashes at full scale value when exceeding 9 V for model 4256-26.
Scaling function Full-scale display: -9999 to +9999 (0 to +9999 for the AC input type)
Offset display: -9999 to +9999 (0 to +9999 for the AC input type)
Resolution 1/10000
Sampling rate 15 times / s
Display cycle with selectable function from 67ms, 400ms, 1s, 2s, 4s, 5s
Input response within 2 samplings or within 1-display cycle, whichever longer
Input method Single ended, floating input
A/D conversion ¨S-∑ conversion method
Noise Rejection Normal mode (NMR) – More than 50 dB.
Common mode (CMR) – More than 110 dB.
Noise through power supply line – 1000 V (at AC voltage power supply)
Comparative digit Figure: 4-digit, Pole: 1-digit
Comparative method 2-isolated contact, programmable of high/low point (for model HI, GO, and LO)
CPU comparative judgement method (against display value)
Setting method by Digital switch setting
Width of hysteresis 1-999, set the same value for 2-comparative output
Comparative display LED display, HI(red), GO(green), and LO(yellow)
Comparative output Relay contact, 1-SPDT Hi and Lo, 250 V 1 A AC (resistive)
NPN Open collector, Max. DC 30 V 30 mA, Max. 1.6 V saturation voltage
Delay output ON delay, 0 to 60 seconds, arbitrary setting by 1 second step from the front switch
(set the same value for 2-comparative output)
Hold Hold for the measuring data, comparative output, and data output
Reset Default the comparative output (break)
Insulation Resistance DC 500 V, More than 100 MΩ
Withstand Voltage Input terminals – External case: AC 1500 V each for 1min.
Power supply terminals – External case: AC 1500 V each for 1min.
Power supply terminals - Input and output terminals: AC 500 V each for 1min.
Power Supply AC 100 to 240 V (50/60 Hz), DC 12 to 24 V
Power Consumption Approx. 5 VA at AC 100 V, 7 VA at AC 200 V, 180 mA at DC 12 V, 90 mA at DC 24 V.
Operating Temperature 0 to 50 °C
Storage Temperature -20 to 70 °C
Weight Approx. 250 g (both AC and DC power supply)

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  

You have 0 items in you cart. Would you like to checkout now?
0 items
Switch to Mobile Version