- Allen-Bradley
- ASHCROFT
- New & Featured Products - HPS high-purity pressure gauge with Reed Switch
- New & Featured Products - S1 Pressure Transducer
- New & Featured Products - ZT12 High Purity Pressure Transmitter
- New & Featured Products - ZX12 High Purity Pressure Transmitter
- Pressure Instruments - Accessories
- Pressure Instruments - Diaphragm Seals-Isolators
- Pressure Instruments - Pressure Gauges
- Pressure Instruments - Pressure Sensors (Transducers/Transmitters)
- Pressure Instruments - Pressure Switches
- Pressure Instruments - SMART Transmitter Assemblies
- Temperature Instruments - MultiPoint Temperature Sensors
- Temperature Instruments - OEM Temperature Sensors
- Temperature Instruments - RTDs
- Temperature Instruments - Temperature Switches
- Temperature Instruments - Thermocouples
- Temperature Instruments - Thermometers
- Temperature Instruments - Thermowells
- Test Instruments - Calibrators
- Test Instruments - Hand Pumps-Controllers
- Test Instruments - Hydraulic Testers
- Test Instruments - Test Gauges
- Cosel
- Euromag
- eYc
- Finetek
- Huba Control
- Koyo
- Maxwell
- MEKKO
- Prokits
- 3C Product Repair Tools
- Aid Tools
- Alignment Tools & Screwdrivers
- Ceramic Driver
- Crimpers
- Cutter
- Drill Bits
- Driver Set
- Electrical Pliers
- Fiber Optics
- Hex Key Wrenches
- Hex Nut Drivers
- Knives & Scissors
- Miscellaneous
- Plier
- Power Tools
- Precision Tweezers
- Punch Down Tools
- Socket Wrenches
- Soldering & Desoldering
- Storage Box
- Strippers
- Test Instruments
- VDE Insulation Tools
- Setra
- Siemens
- SIMEX
- Sondar
- SURE INSTRUMENTS
- Suto
- Tsuruga
- VAISALA
- VE-PURE
- WELTEM
- Winters Instruments
TECH IMPRO AUTOMATION SOLUTION SDN BHD
7263, 1st Floor, Lorong Chempa, 12200 Butterworth, Penang, Malaysia.
TSURUGA Edgewise shape Indicator for Model TME, TCE, TAE series
Previous | 3 / 5 | Next |
Specification
Model | T¡õE-45A | T¡õE-60C | T¡õE-80B | T¡õE-100A | T¡õE-120 | T¡õE-152 | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Symbol of operating principles |
Each '¡õ' symbol is filled with operating principle below.
|
|||||||||||||
Standard Specification | Dimension | 44.5 x 13 mm | 60 x 22 mm | 80 x 16 mm | 100 x 30 mm | 120 x 46 mm | 152.3 x 50.7 mm | |||||||
Weight (1 mA DC rated) |
0.04kg | 0.14kg | 0.175kg | 0.23kg | 0.55kg | 1.1kg | ||||||||
Operating Principles |
|
|||||||||||||
Accuracy Class | Class 2.5 | Class 1.5 | ||||||||||||
Length of Scale | 34.5 mm | 46 mm | 64 mm | 82 mm | 80 mm | 100 mm | ||||||||
Shape of pointer | Red bar | Red, flat | Red, larger bar | |||||||||||
Color of indicator panel | White | |||||||||||||
Color of cover | Transparent (anti-static resin) | Black | ||||||||||||
Test Voltage | Terminal/Outer case More than AC 2210 V 5sec. | |||||||||||||
Operating temperature | 0 to 40 ¡æ | |||||||||||||
Operating humidity | 30 to 90 %RH (No Condensing) | |||||||||||||
Standard Rated Input |
DC Ammeter (Moving coil) |
50 μA, 100 μA, 500 μA, 1 mA, 10 mA |
50 μA, 100 μA, 1 mA, 10 mA to 1 A |
100 μA, 1 mA, 10 mA to 1 A |
1 mA, 10 mA to 20 A |
1 mA | ||||||||
DC Voltmeter (Moving coil) |
1 V to 100 V | 1 V to 150 V | 1 V to 300 V | |||||||||||
Receiving meter (Moving coil) |
4 to 20 mA 1 to 5 V (4 kΩ£© 1 to 5 V (1 MΩ, with external Converter 7331) |
4 to 20 mA 1 to 5 V (4 kΩ£© 1 to 5 V (1 MΩ) |
||||||||||||
AC Ammeter | Rectifier type | - | 1 mA | 1 mA to 300 mA | 1 mA | |||||||||
RMS effective value type | 1 A to 30 A (with external Converter 7311) |
1 A to 5 A (built-in CT) 10 A to 30 A (with Converter 7311) |
||||||||||||
AC Voltmeter |
10 V to 300 V (with Multiplier) |
10 V to 150 V | 10 V to 300 V |
¡òTwice or three times extended scale can be manufactured if the rated current of AC Ammeter is more than 1 A.
¡òWhen the rated value is exceeded in DC Ammeter, connect the shunt and analog meter with 60 mV rated value (except T¡õE-152).
¡òWhen the rated valueis exceeded in DC voltmeter, connect the multiplier and analog meter with 1 mA rated voltage.
¡òWhen the rated value is exceeded in AC Ammeter, connect the current transformer (CT) with analog meter with 5 A rated current.
¡òWhen the rated value is exceeded in AC voltmeter, connect voltage transformer (VT) and analog meter with 100 V rated voltage.
Customers are requested to provide the following information during order.
- 1. Model
- 2. Rated input value
- 3. Scale and Unit
-
4. Vertical or Horizontal installation
¡ùReceiving meter of DC 1 to 5 V (1 MΩ£©needs power supply.