- Allen-Bradley
- ASHCROFT
- New & Featured Products - HPS high-purity pressure gauge with Reed Switch
- New & Featured Products - S1 Pressure Transducer
- New & Featured Products - ZT12 High Purity Pressure Transmitter
- New & Featured Products - ZX12 High Purity Pressure Transmitter
- Pressure Instruments - Accessories
- Pressure Instruments - Diaphragm Seals-Isolators
- Pressure Instruments - Pressure Gauges
- Pressure Instruments - Pressure Sensors (Transducers/Transmitters)
- Pressure Instruments - Pressure Switches
- Pressure Instruments - SMART Transmitter Assemblies
- Temperature Instruments - MultiPoint Temperature Sensors
- Temperature Instruments - OEM Temperature Sensors
- Temperature Instruments - RTDs
- Temperature Instruments - Temperature Switches
- Temperature Instruments - Thermocouples
- Temperature Instruments - Thermometers
- Temperature Instruments - Thermowells
- Test Instruments - Calibrators
- Test Instruments - Hand Pumps-Controllers
- Test Instruments - Hydraulic Testers
- Test Instruments - Test Gauges
- Cosel
- Euromag
- eYc
- Finetek
- Huba Control
- Koyo
- Maxwell
- MEKKO
- Prokits
- 3C Product Repair Tools
- Aid Tools
- Alignment Tools & Screwdrivers
- Ceramic Driver
- Crimpers
- Cutter
- Drill Bits
- Driver Set
- Electrical Pliers
- Fiber Optics
- Hex Key Wrenches
- Hex Nut Drivers
- Knives & Scissors
- Miscellaneous
- Plier
- Power Tools
- Precision Tweezers
- Punch Down Tools
- Socket Wrenches
- Soldering & Desoldering
- Storage Box
- Strippers
- Test Instruments
- VDE Insulation Tools
- Setra
- Siemens
- SIMEX
- Sondar
- SURE INSTRUMENTS
- Suto
- Tsuruga
- VAISALA
- VE-PURE
- WELTEM
- Winters Instruments
TECH IMPRO AUTOMATION SOLUTION SDN BHD
7263, 1st Floor, Lorong Chempa, 12200 Butterworth, Penang, Malaysia.
+6012-466 1514
TSURUGA MODEL 2400D/2400S
¡öSuitable for overload protection and abnormal detection of motor.
¡öMax. 20 signals can be obtained for just 1 signal input.
¡öTwo types of setting are available : Digital type and screw type
Model
Model
Note: Auxiliary unit 2422 is used together with the main unit 2411 or 2421. It can not be connected to some of AC input models.
Product Name | 1ch Main Unit | 2ch Main Unit | 2ch Auxiliary Alarm Output Unit | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Model Configuration |
|
|
|
Code | 2411 | 2421 | 2422 |
---|---|---|---|
D | Digital switch setting | ||
S | Screw driver setting |
Code | 2411 | 2421 | 2422 |
---|---|---|---|
1 | H Setting, relay contact output | HL Setting, relay contact output | |
2 | L Setting, relay contact output | HH Setting, relay contact output | |
3 | H Setting, open collector output | LL Setting, relay contact output | |
4 | L Setting, open collector output | HL Setting, open collector output | |
5 | -------------------- | HH Setting, open collector output | |
6 | -------------------- | LL Setting, open collector output |
Code | 2411 | 2421 | 2422 | |
---|---|---|---|---|
-- | DC signal |
Note: 2422 is the auxiliary unit, so it accepts no input signal and no specification of ¢Û is required. |
||
02 | DC 0 to 100 mV | |||
03 | DC 0 to 1 V | |||
04 | DC 0 to 5 V | |||
05 | DC 0 to 10 V | |||
09 | DC 1 to 5 V | |||
00 | Other DC voltage input (60 mV¨Q00 ¨Q300 V) | |||
22 | DC 0 to 100 μA | |||
23 | DC 0 to 1 mA | |||
24 | DC 0 to 5 mA | |||
25 | DC 0 to 10 mA | |||
29 | DC 4 to 20 mA | |||
20 | Other DC current input (100 μA¨Q20 ¨Q1 A) | |||
- | AC signal (Effective value rectification type) | |||
44 | AC 0 to 150 V rms | |||
46 | AC 0 to 300 V rms | |||
40 | (100 mV¨Q40¨Q300 V) | |||
53 | AC 0 to 1 A rms | |||
54 | AC 0 to 5 A rms | |||
50 | (100 mA¨Q50¨Q5 A) | |||
- | AC signal (Rectification type) | |||
73 | AC 0 to 1 A | ¡ùHalf wave peak detection system | ||
74 | AC 0 to 5 A | |||
70 | (100 mA¨Q70 ¨Q5 A) |
¡ùConnection with 2422, 2ch Auxiliary Alarm Output Unit,is not possible.
Specifications/Model
Specification / Model | 2411D/2411S | 2421D/2421S | 2422D/2422S | ||
---|---|---|---|---|---|
D : Digital switch setting S : Screw driver setting |
|||||
Dimension (W x H x D mm) excl .Base socket | 28.5 × 72 × 115 | ||||
Input | DC current / voltage(Moving coil) | ¡ñ | ¡ñ | - | |
Process | ¡ñ | ¡ñ | - | ||
AC current / voltage | ¡ñ | - | - | ||
Output | Nos. of Alarm | 1point | ¡ñ | - | - |
2points | - | ¡ñ | ¡ñ | ||
Accuracy | Setting (exclude pot.setting) | within ± 0.5 % of Max.value | |||
Repeatability | within ± 0.1 % | ||||
Output | Relay | ¡ñ | ¡ñ | ¡ñ | |
Open collector | ¡ð | ¡ð | ¡ð | ||
Setting style | Thumb | ¡ñ | ¡ñ | ¡ñ | |
Potentiometer | ¡ñ | ¡ñ | ¡ñ | ||
Alarm type (H/L) | H or L fixed | ¡ñ | ¡ñ | ¡ñ | |
Rating | Relay | 250 V, 0.5 A a.c., 30 V, 2 A d.c. | |||
Open collector | 50 V, 100 mA¡¡d.c.¡¡ | ||||
Response |
|
||||
Function | Hysteresis | ¡ð | ¡ð | ¡ð | |
Output delay | ¡ð | ¡ð | ¡ð | ||
Power on delay | ¡ñ | ¡ñ | ¡ñ | ||
Operating temperature | 0-50°C | ||||
Operating humidity | 30 - 90%RH (no condensation) | ||||
AC power supply | 85 – 264 V a.c. | ||||
DC power supply | 20 – 30 V d.c., 90 – 170 V d.c. | ||||
Weight | approx. 170 g |
¡ñ£ºStandard, ¡ð£ºOption