TECH IMPRO AUTOMATION SOLUTION SDN BHD
7263, 1st Floor, Lorong Chempa, 12200 Butterworth, Penang, Malaysia.
+6012-466 1514

TSURUGA MODEL NRE-65AH/NRE-65AHL

Previous 4 / 9 Next

TSURUGA MODEL NRE-65AH/NRE-65AHL Meter Relay Analog Instrument Tsuruga
Quantity
Add Quotation


・Lineup with 3 edgewise types of Meter Relay.
・Suitable for display and control of tank capacity and level.
・Bright panel surface and easy to read values.

Specification / Model NRE-65AH
NRE-65AHL
NRE-100AH
NRE-100AHL
NRE-152H
NRE-152HL
NRE - ¡õ ¡õ
    ¢Ù ¢Ú
¢Ù Size
65A
100A
152
 
¢Ú Setting
HL
H


 
H : High value setting, relay contact output HL : High and Low value setting, relay contact output
Dimension
(mm)
22(W)×65(H) ¡ñ - -
30(W)×100(H) - ¡ñ -
50.7(W)×152.3(H) - - ¡ñ
Weight
(1 mA d.c. rated)
  approx. 150 g approx. 320 g approx. 1,300 g
TYPE Edgewise
Input (*1) DC Current (Moving coil) 10 μA - 1A 100 μA,
1mA,
10 mA - 1 A
1 mA
DC Voltage (Moving coil) 10 mV - 300 V 1 V - 300 V
Process (Moving coil) 4 - 20mA,
1 - 5 V(500kΩ)
4 - 20mA,
1 - 5 V(4kΩ),
1 - 5 V
(w / 1MΩ / 7331)
4 - 20mA,
1 - 5 V(4kΩ),
1 - 5 V(1MΩ)
AC Current (average) 1 - 300mA
£¨w / 7331£©
1 - 300mA 1mA
(r.m.s., 1A or more) 1 - 30 A
( w / 7311)
1 - 5 A
(CT incorporated),
10 -30 A
(w / 7311)
AC Voltage (average) 10 - 300V
Display Accuracy Class 1.5 - ¡ñ ¡ñ
Class 2.5 ¡ñ - -
Scale length 44 mm 82 mm 100 mm
Scale divisions 20 - 37.5 ¡ñ - ¡ñ
30 - 50 - ¡ñ -
Scale Pointer Needle type, red Flat Type, red Large type, red
Scale plate color White
Cover color Black - - ¡ñ
7.5BG4/1.5 - - ¡ð
Transparence
(non-electrification resin)
¡ñ ¡ñ -
Output Operation type Optical - ¡ñ ¡ñ
Electrical ¡ñ - -
Output Hold (relay)
Pointer Knife shape H(High) : Red, L(Low) : Green
Setting range 0 - 100% of scale for H and L
Setting HL (High / Low )¡¡or¡¡H £¨High)
minimum setting range(*2) Less than 3 %
Pick up accuracy(*2) Less than 2.5 % Less than 1.0 %
Deadband (*2) Less than 0.5 %
Temp. coefficient (*2)
(pick up value change at rated voltage ± 10 %)
Less than 0.5 % Less than 0.3 %
Power regulation (*2)
(pick up value change at rated voltage ± 10 %)
Less than 0.5 % Less than 0.3 %
Output contact 1 transfer for H and L
(NRE-152: N/O or N/C selectable)
Contact rate (load resistance) 250 V, 2 A a.c.
220 V, 2 A d.c.
230 V, 3 A a.c.
30 V, 3 A d.c.
230V, 2.5A a.c.
30V, 2.5A d.c.
100/110,200/220V AC (w / transformer **) ¡ñ(*3) ¡ñ ¡ñ (*4)
24V DC ¡ð ¡ð ¡ð
Power consumption approx. 2VA 2.5VA or less 3VA or less
Operating temperature 0 – 50°C
Operating humidity 30 - 90%RH (no condensation)
*1
When the rated input exceeds the specific standard, accessory is included with product.
*2
It is the value against the scale length.
*3
The power supply terminal is not insulated from the measurement input terminal. If the transformer is not used, insulate the measurement input from the power supply.
*4
The power source and the input are not insulated in the receiver (1 to 5V, 1MΩ). Insulate the measurement input and power supply when needed.

¡ñ£ºStandard, ¡ð£ºOption

Customers are requested to provide the following information during order.

  1. 1. Model ( HL or H )
  2. 2. Rated value (Input signal with AC or DC type)
  3. 3. Scale and Unit
  4. 4. Position (Horizontal or Vertical )
  5. 5. Power supply
    ・AC 100/110 V ± 10% or AC 200/220 V ± 10% ( 50/60 Hz )
    ・DC 24V ± 10%