- Allen-Bradley
- ASHCROFT
- New & Featured Products - HPS high-purity pressure gauge with Reed Switch
- New & Featured Products - S1 Pressure Transducer
- New & Featured Products - ZT12 High Purity Pressure Transmitter
- New & Featured Products - ZX12 High Purity Pressure Transmitter
- Pressure Instruments - Accessories
- Pressure Instruments - Diaphragm Seals-Isolators
- Pressure Instruments - Pressure Gauges
- Pressure Instruments - Pressure Sensors (Transducers/Transmitters)
- Pressure Instruments - Pressure Switches
- Pressure Instruments - SMART Transmitter Assemblies
- Temperature Instruments - MultiPoint Temperature Sensors
- Temperature Instruments - OEM Temperature Sensors
- Temperature Instruments - RTDs
- Temperature Instruments - Temperature Switches
- Temperature Instruments - Thermocouples
- Temperature Instruments - Thermometers
- Temperature Instruments - Thermowells
- Test Instruments - Calibrators
- Test Instruments - Hand Pumps-Controllers
- Test Instruments - Hydraulic Testers
- Test Instruments - Test Gauges
- Autonics
- Cosel
- Euromag
- eYc
- Finetek
- Huba Control
- Koyo
- KROHNE
- Maxwell
- MEKKO
- Prokits
- 3C Product Repair Tools
- Aid Tools
- Alignment Tools & Screwdrivers
- Ceramic Driver
- Crimpers
- Cutter
- Drill Bits
- Driver Set
- Electrical Pliers
- Fiber Optics
- Hex Key Wrenches
- Hex Nut Drivers
- Knives & Scissors
- Miscellaneous
- Plier
- Power Tools
- Precision Tweezers
- Punch Down Tools
- Socket Wrenches
- Soldering & Desoldering
- Storage Box
- Strippers
- Test Instruments
- VDE Insulation Tools
- RITTAL
- Accessories for Climate Control
- Climate Control
- Accessories for IT cooling
- Air-air Heat Exchanger
- Air-water Heat Exchanger
- Chillers
- Cooling units, Thermoelectric Cooler
- Direct Air Cooling (DAC) systems for multifunctional enclosures
- Enclosure heater with fan
- Fan-and-filter Units, Roof-mounted fans, Rack-mounted Fans
- Heaters
- Hose-proof hood to increase the protection category
- IT Cooling - Aisle Containment
- IT Cooling - IT Room Cooling, Chiller, Roof-mounted cooling units for cooling IT equipment
- IT Cooling - Liquid Cooling Package
- IT Cooling - Small Cooling Unit
- Modular Climate Control Concept - Cooling module "Blue e" Total cooling output 1.50 - 2.50 kW
- Modular climate control concept ¨C Climate control door VX25 for installing cooling modules
- Setra
- Siemens
- SIMEX
- Sondar
- SURE INSTRUMENTS
- Suto
- Tsuruga
- VAISALA
- VE-PURE
- WELTEM
- Winters Instruments
TECH IMPRO AUTOMATION SOLUTION SDN BHD
25, Jalan Chain Ferry, Taman Chai Leng, 13700 Perai, Pulau Pinang, Malaysia.
+6012-466 1514
TSURUGA MODEL 3568
| Previous | 2 / 2 | Next |
- ¡ö6 ranges from 300 mΩ to 30 kΩ are available
- ¡ö4-terminal method minimizes the resistance of lead wire
- ¡öAvailable with AC or battery pack power supply
- ¡öLight weight: 1 kg
Specification
| Measurement range Note 1 | 30 mΩ | 300 mΩ | 3 Ω |
|---|---|---|---|
| Resolution | 1 μΩ | 10 μΩ | 100 μΩ |
| Measuring current | 7.4 mA | 1 mA | 100 μA |
| Accuracy Note 2 | ± (0.5 % of rdg. + 8 dgt.) | ||
| Temperature coefficient | ± (0.05 % of rdg. + 0.8 dgt.) / ¡æ | ||
| Open terminal voltage | Less than 20 mV peak (with OFF function) | ||
| Measurement range Note 1 | ± 5 V | ± 50 V |
|---|---|---|
| Resolution | 100 μV | 1 mV |
| Accuracy Note 2 | ± (0.05 % of rdg. + 5dgt.) | |
| Temperature coefficient | ± (0.005 % of rdg. +0.5 dgt.) / ¡æ | |
Note1: All CH, the same range
Note 2: Specified at 23 ¡æ ± 5 ¡æ, 45 to 75 % RH
| Measuring method | AC 4 terminal method (Resistance measurement) | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Measuring frequency | AC 1 kHz ± 20 Hz (Resistance measurement) | |||||||||||
| Sampling cycle | 10 times / s. (Resistance, voltage measurement) | |||||||||||
| Measurement terminal | Connector of 2.54 mm pitch, MIL-C-86503 standard | |||||||||||
| Wiring resistance | Source side: Less than 0.1 Ω | |||||||||||
| Display |
LCD display Resistance measurement: 35000 Voltage measurement: 50000 (with polarity indication) |
|||||||||||
| Measuring mode |
|
|||||||||||
|
Measuring time (During automatic measurement) |
Select 1 s. or 2 s. for one CH Measuring time of 1 s.:aprx. 900 ms., 2 s.: aprx.1900 ms. |
|||||||||||
| Judgment |
Upper limit (H1, H2) can be set.
|
|||||||||||
| Insulation resistance | DC 500 V, more than 50 MΩ | |||||||||||
| Withstanding voltage | AC 1500 V, 1 min. | |||||||||||
| Power supply tolerance | AC 90 to 250 V (356M, 5811-71) | |||||||||||
| Operating ambient temperature | 0 to 50 ¡æ | |||||||||||
| Storage temperature | -20 to 70 ¡æ | |||||||||||
| Weight | 356M aprx. 1 kg, 5811-71 aprx. 1 kg | |||||||||||
| Dimension | 205 (W) x 64 (H) x 169 (D) mm | |||||||||||
| Serial communication RS-232C |
|
|||||||||||
| Accessory |
|
|||||||||||
|
||||||||||||
| Measurement cable | Not included, manufacturable based on meeting with us. |
Application
Internal resistance of Battery, contact resistance etc.