- Allen-Bradley
- ASHCROFT
- New & Featured Products - HPS high-purity pressure gauge with Reed Switch
- New & Featured Products - S1 Pressure Transducer
- New & Featured Products - ZT12 High Purity Pressure Transmitter
- New & Featured Products - ZX12 High Purity Pressure Transmitter
- Pressure Instruments - Accessories
- Pressure Instruments - Diaphragm Seals-Isolators
- Pressure Instruments - Pressure Gauges
- Pressure Instruments - Pressure Sensors (Transducers/Transmitters)
- Pressure Instruments - Pressure Switches
- Pressure Instruments - SMART Transmitter Assemblies
- Temperature Instruments - MultiPoint Temperature Sensors
- Temperature Instruments - OEM Temperature Sensors
- Temperature Instruments - RTDs
- Temperature Instruments - Temperature Switches
- Temperature Instruments - Thermocouples
- Temperature Instruments - Thermometers
- Temperature Instruments - Thermowells
- Test Instruments - Calibrators
- Test Instruments - Hand Pumps-Controllers
- Test Instruments - Hydraulic Testers
- Test Instruments - Test Gauges
- Cosel
- Euromag
- eYc
- Finetek
- Huba Control
- Koyo
- Maxwell
- MEKKO
- Prokits
- 3C Product Repair Tools
- Aid Tools
- Alignment Tools & Screwdrivers
- Ceramic Driver
- Crimpers
- Cutter
- Drill Bits
- Driver Set
- Electrical Pliers
- Fiber Optics
- Hex Key Wrenches
- Hex Nut Drivers
- Knives & Scissors
- Miscellaneous
- Plier
- Power Tools
- Precision Tweezers
- Punch Down Tools
- Socket Wrenches
- Soldering & Desoldering
- Storage Box
- Strippers
- Test Instruments
- VDE Insulation Tools
- Setra
- Siemens
- SIMEX
- Sondar
- SURE INSTRUMENTS
- Suto
- Tsuruga
- VAISALA
- VE-PURE
- WELTEM
- Winters Instruments
TECH IMPRO AUTOMATION SOLUTION SDN BHD
7263, 1st Floor, Lorong Chempa, 12200 Butterworth, Penang, Malaysia.
+6012-466 1514
TSURUGA MODEL 356G
Previous | 2 / 3 | Next |
- ¡öDisplay by six digits, Minimum resolution 0.1μΩ
- ¡öOutput RS-232C is standard instrument.
- ¡öAvailable with Data output BCD and RS-485
- ¡öAvailable with temp. measurement function and possible for temp. corretion measurement.
- ¡öMeasured value can be output by average value. The average number of data can be set from 2 to 100
Specification
ApplicationMeasurement ranges | 30 m, 300 mΩ, 3, 30, 300 Ω, 5 ranges |
---|---|
Accuracy |
± (0.1% of rdg. + 30digit) / ± (0.08% of rdg. + 25 digit) at SLOW & MEDIUM sampling mode ± (0.2% of rdg. + 10digit) at FAST sampling mode |
Measurement current | From DC 1 A to 10 mA |
Max. Applied voltage | 50 V DC for all ranges |
Sampling time | 80/sec (FAST mode), 20/sec (MEDIUM mode), 5/sec (SLOW mode) |
Response speed | 30 ms (FAST mode), 100 ms (MEDIUM mode), 500 ms (SLOW mode) |
Measurement method | Four-terminal measurement |
Measuring temperature | From -19.9 °C to 199.9 °C |
Power supply | 90 to 250 V AC, 50/60 HZ |
Weight | 2.8 kg |
Dimensions | 205 (W) x 65 (H) x 300 (D) mm |
Accessories | Power fuse(1), Power cord(1), Input connector (1) |
Coil, Power Supply Switch, Lead, Conductor