- Allen-Bradley
- ASHCROFT
- New & Featured Products - HPS high-purity pressure gauge with Reed Switch
- New & Featured Products - S1 Pressure Transducer
- New & Featured Products - ZT12 High Purity Pressure Transmitter
- New & Featured Products - ZX12 High Purity Pressure Transmitter
- Pressure Instruments - Accessories
- Pressure Instruments - Diaphragm Seals-Isolators
- Pressure Instruments - Pressure Gauges
- Pressure Instruments - Pressure Sensors (Transducers/Transmitters)
- Pressure Instruments - Pressure Switches
- Pressure Instruments - SMART Transmitter Assemblies
- Temperature Instruments - MultiPoint Temperature Sensors
- Temperature Instruments - OEM Temperature Sensors
- Temperature Instruments - RTDs
- Temperature Instruments - Temperature Switches
- Temperature Instruments - Thermocouples
- Temperature Instruments - Thermometers
- Temperature Instruments - Thermowells
- Test Instruments - Calibrators
- Test Instruments - Hand Pumps-Controllers
- Test Instruments - Hydraulic Testers
- Test Instruments - Test Gauges
- Cosel
- Euromag
- eYc
- Finetek
- Huba Control
- Koyo
- Maxwell
- MEKKO
- Prokits
- 3C Product Repair Tools
- Aid Tools
- Alignment Tools & Screwdrivers
- Ceramic Driver
- Crimpers
- Cutter
- Drill Bits
- Driver Set
- Electrical Pliers
- Fiber Optics
- Hex Key Wrenches
- Hex Nut Drivers
- Knives & Scissors
- Miscellaneous
- Plier
- Power Tools
- Precision Tweezers
- Punch Down Tools
- Socket Wrenches
- Soldering & Desoldering
- Storage Box
- Strippers
- Test Instruments
- VDE Insulation Tools
- Setra
- Siemens
- SIMEX
- Sondar
- SURE INSTRUMENTS
- Suto
- Tsuruga
- VAISALA
- VE-PURE
- WELTEM
- Winters Instruments
TECH IMPRO AUTOMATION SOLUTION SDN BHD
7263, 1st Floor, Lorong Chempa, 12200 Butterworth, Penang, Malaysia.
+6012-466 1514
TSURUGA MODEL 850A
Previous | 4 / 4 | Next |
-
¡öWithstand voltage test AC 0 to 5 kV, leak current setting 0.00 to 99.99 mA
Insulation resistance test DC 500/1000 V, measuring range 0 to 9990 MΩ - ¡öRise- and Fall-time of withstand voltage tests can be arranged.
- ¡öRemote I/O and RS-232C interfaces are equipped.
- ¡öClear and easy to read color LCD
Withstand voltage test
Test voltage | |||||||
---|---|---|---|---|---|---|---|
Output voltage | AC 0.2 to 5.00 kV (50 Hz and 60 Hz switchable) | ||||||
Output capacity |
500 VA (5 kV, 100 mA) Continuous application time of the maximum current output within 1 min. |
||||||
Wave form | Sine wave ( Rate of strain: Less than 5 %, when No-load applied.) | ||||||
Power frequency | 50 / 60 Hz | ||||||
Voltage fluctuation rate | Less than 15 % (Maximum rating ➔ No-load: in resistive load) | ||||||
Voltage application method | Zero cross switch | ||||||
Voltage measurement | |||||||
Rectification method | Average rectified effective value display | ||||||
Digital display | Applied voltage is displayed during test, and the value is retained after the test end. | ||||||
Measurement accuracy | ± (0.5 % of F.S + 10 V) | ||||||
Current measurement | |||||||
Rectification method | Average rectified effective value display | ||||||
Digital display |
Measurement range 0.00 to 99.99 mA Leakage current is displayed during test, and the value is retained after the test end. |
||||||
Judgment method |
|
||||||
Setting range |
|
||||||
Judgment conditions |
|
||||||
Test time | |||||||
Setting range | 00:00.2 to 99:59.9 s and OFF (continuous) | ||||||
Setting resolution | 0.1 s | ||||||
Time display |
|
||||||
Setting accuracy | Set value ± (0.1 % + 20 ms) | ||||||
Rise time | |||||||
Function | Voltage rises linearly till test value in setting time. | ||||||
Setting range |
00:00.1 to 01:59.9 s and OFF Setting resolution 0.1 s |
||||||
Setting accuracy | Set value ± (0.1 % + 20 ms) | ||||||
Fall time | |||||||
Function | Voltage falls linearly from test value to 0 V in setting time. | ||||||
Setting range |
00:00.1 to 01:59.9 s and OFF Setting resolution 0.1 s |
||||||
Setting accuracy | Set value ± (0.1 % + 20 ms) |
Insulation resistance test
Test voltage | |||||||
---|---|---|---|---|---|---|---|
Rated measuring voltage | DC 500 V/ 1000 V | ||||||
Open circuit voltage | Within 125 % of rated measuring voltage | ||||||
Rated measuring current | 1 mA | ||||||
Short circuit current | Less than 15 mA | ||||||
Display |
0 to 9990 MΩ Zero suppress Auto range Insulation resistance is displayed during test. Resistance value at the end of test is retained. |
||||||
Test judgment | |||||||
Judgment method | Upper and Lower limit by digital comparator | ||||||
Setting range | 0.01 to 99.99 MΩ/0.1 to 999.9 MΩ/1 to 9999MΩ | ||||||
Judgment conditions |
|
||||||
Test time | |||||||
Setting range |
00:00.2 to 99:59.9 s and OFF Setting resolution 0.1s |
||||||
Setting accuracy | Set value ± (0.1 % + 20 ms) | ||||||
Time display |
|
||||||
Response time |
Display response and judgment time (medium value).
|
||||||
Mask time | |||||||
Setting range |
00:00.1 to 01:59.9 s and OFF Setting resolution 0.1 s Mask time < Test time |
||||||
Discharge function | |||||||
Electric charge on specimen can be discharged. |
Interface
RS-232C Utility software is optional. | |
---|---|
Function | To set test conditions and output judgment results. |
Connector | D-sub 9P |
Transmission system | Asynchronous method |
Transmission speed | 9600/19200/38400 bps |
Data length | 8 bit |
Parity | None/Even/Odd |
Specification
Power supply | AC 100 to 240 V 50/60 Hz | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Power supply voltage tolerance range | AC 90 to 250 V | ||||||||||
Power consumption |
|
||||||||||
Operation ambient temperature | 0 to 40 ¡æ | ||||||||||
Operation ambient humidity | 20 to 80 %RH (No-condensing) | ||||||||||
Storage temperature | -20 to 70 ¡æ | ||||||||||
Withstand voltage | Power terminal - Outer box AC 1350 V 1min | ||||||||||
Dimensions | 320 (W) x 150 (H) x 430 (D) (Unit: mm) | ||||||||||
Weight | Approx. 18 kg | ||||||||||
Accessory |
|
||||||||||
Option | |||||||||||
|
Application
Motor and Generator, Spark plugs, Capacitors, Connectors, Aviation components, Transformers, Wire and Cables, Coils and Chokes, Switches and Relays