- Allen-Bradley
- Cosel
- Euromag
- eYc
- Finetek
- Huba Control
- Koyo
- Maxwell
- MEKKO
- Prokits
- 3C Product Repair Tools
- Aid Tools
- Alignment Tools & Screwdrivers
- Ceramic Driver
- Crimpers
- Cutter
- Drill Bits
- Driver Set
- Electrical Pliers
- Fiber Optics
- Hex Key Wrenches
- Hex Nut Drivers
- Knives & Scissors
- Miscellaneous
- Plier
- Power Tools
- Precision Tweezers
- Punch Down Tools
- Socket Wrenches
- Soldering & Desoldering
- Storage Box
- Strippers
- Test Instruments
- VDE Insulation Tools
- Rotronic
- Setra
- Siemens
- SIMEX
- Sondar
- Suto
- Tsuruga
- VAISALA
- VE-PURE
- WELTEM
- Winters Instruments
TECH IMPRO AUTOMATION SOLUTION SDN BHD
7263, 1st Floor, Lorong Chempa, 12200 Butterworth, Penang, Malaysia.
+6012-466 1514
eYc DST01 Universal Isolating Signal Converter / Splitter
Previous | 1 / 11 | Next |
Signal isolation:Power supply;Analog input
3 groups of analog output
1 set RS-485 output
Accuracy:±0.05% of span ±0.0025% / °C
Output signal:4 ... 20 mA, DC 0 ... 10 V
Description
DST01 The signal conditioner incorporates two bright and easy to read LCD displays which indicate process value (PV) and user selected parameter.
Powered by a DC 12 ... 38 V or AC 95 ... 250 V supply. It is fully programmable for linear voltage, linear current, Pt100 and thermocouple types such as J, K, T, E, B, R, S, N, L, U, P, C, and D input. Its fast sampling rate allows the signal conditioner to retransmit the signal faster, the maximum of 3 retransmission with one input.
Specification
Application
Chemical industry / Energy / Oil & gas / Marine / Water circulation system / Factory automation / Metal & steel / Cement / Pulp & paper / Pharmaceuticals / Food & beverage

3 groups of analog output
1 set RS-485 output
Accuracy:±0.05% of span ±0.0025% / °C
Output signal:4 ... 20 mA, DC 0 ... 10 V
Description
- Signal isolation:Power supply;Analog input
- 3 groups of analog output
- 1 set RS-485 output
- Multiple input signals
- LED display working status
- Easy button operation
- DIN rail installation, high safety & stability
DST01 The signal conditioner incorporates two bright and easy to read LCD displays which indicate process value (PV) and user selected parameter.
Powered by a DC 12 ... 38 V or AC 95 ... 250 V supply. It is fully programmable for linear voltage, linear current, Pt100 and thermocouple types such as J, K, T, E, B, R, S, N, L, U, P, C, and D input. Its fast sampling rate allows the signal conditioner to retransmit the signal faster, the maximum of 3 retransmission with one input.
Specification
Power | Power supply | AC 95 ... 250 V, DC 12 ... 38 V |
Power consumption | 10 VA, 5 W maximum | |
Signal input | Type |
Thermocouple(J, K, T, E, B, R, S, N, L, U, P, C, D), RTD(Pt100(DIN), Pt100(JIS)), current(mA), voltage(V) |
Sampling rate | 5 Times / Second(200 msec) | |
Temperature effect | 1.5 μV / °C for all inputs except mA input, 3.0 μV / °C for mA | |
Sensor lead resistance effect |
Thermocouple:0.2 μV / Ω ; 3-wire RTD:2.6°C / Ω of difference of resistance of two leads 2-wire RTD:2.6°C / Ω of sum of resistance of two leads |
|
Burn-out current | 200 nA | |
Common mode rejection ratio(CMRR) |
120 dB | |
Normal mode rejection ratio(NMRR) |
55 dB | |
Sensor break detection |
Sensor open for thermocouple, RTD and mV inputs, sensor short for RTD input, below 1 mA for 4 ... 20 mA input, below DC 0.25 V for DC 1 ... 5 V input, not available for other inputs |
|
Sensor break response time |
within 4 seconds for thermocouple, RTD and mV inputs, 0.1 second for 4 ... 20 mA and DC 1 ... 5 V inputs |
|
Analog retransmission output 1 output 2 output 3 |
Number of outputs | 3 |
Output signal | 4 ... 20 mA, DC 0 ... 10 V | |
Accuracy | ±0.05% of span ±0.0025% / °C | |
Load resistance | 0 ... 500 Ω for current output, 10 KΩ minimum for voltage output | |
Output regulation | 0.01% for full load change | |
Output setting | Time 0.1 second(Stable to 99.9%) | |
Isolation breakdown | AC 1000 V minimum | |
Integral linearity error | ±0.005% of span | |
Temperature effect | ±0.0025% of span / °C | |
Data communication |
Interface | RS-485 |
Protocol | Modbus RTU(Slave mode) | |
Address | 1 ... 247 | |
Baud rate | 2.8 ... 115.2 KBPS | |
Parity bit | None, even or odd | |
Stop bit | 1 or 2 bits | |
data length | 7 or 8 bits | |
Communication buffer | 160 bytes | |
User interface | Key / Display |
Keypad:4 keys 4 Digit LCD display;No of display 2 Upper:0.58”(15 mm);Lower:0.3”(7.8 mm) |
Digital filter | Function | First order |
Time constant | 0, 0.2, 0.5, 1, 2, 5, 10, 20, 30, 60 seconds, programmable | |
Environmental and physical specifications |
Temperature | Operating:-10 ... 50°C;Storage:-40 ... 60°C |
Humidity | 0 ... 90%RH(Non-condensing) | |
Altitude | 2000 meters maximum | |
Pollution | Degree II | |
Insulation resistance | 20 MΩ minimum(at DC 500 V) | |
Dielectric strength | AC 2000 V, 50 / 60 Hz for 1 minute | |
Vibration resistance | 10 ... 55 Hz, 10 m/s2 for 2 hours | |
Shock resistance | 200 m/s2(20g) | |
Dimensions / Weight | W22.5xH96xD83 mm / 160g | |
Approval standards |
IP rating | IP65 for panel(in process), IP20 for terminals and housing(Indoor) |
EMC | EN61326 |
Application
Chemical industry / Energy / Oil & gas / Marine / Water circulation system / Factory automation / Metal & steel / Cement / Pulp & paper / Pharmaceuticals / Food & beverage