TECH IMPRO AUTOMATION SOLUTION SDN BHD
7263, 1st Floor, Lorong Chempa, 12200 Butterworth, Penang, Malaysia.
+6012-466 1514

eYc Ozone Analyzer

Previous 6 / 10 Next

eYc Ozone Analyzer Gas ( CO / CO2 ) / Air quality eYc
Quantity
Add Quotation


Note:This product only available in Taiwan, China and Hong Kong.
Applicable to measurement and analysis of environmental protection industries such as semiconductor, agriculture, water resources, etc.
UV-D photometric method determination of ozone concentration, traceable to NIST international standards
Measuring range:
Standard type(User-range):1000 ppmv
Standard type(Auto-range):1 ... 100 ppm
Resolution:
Standard type(User-range):Min. 0.1 ppmv at 1000 ppm
Standard type(Auto-range):Min. 0.1 ppbv at 1 ppm

Description

  • UV-D photometric method determination of ozone concentration, traceable to NIST international standards
  • Wide measuring range / Dynamic full-range measurement mode
  • Quickly switch between measuring range and concentration unit(Six types)
  • LCD, display of concentration, temperature and pressure
  • Automatic temperature and pressure compensation / Built-in aspirator pump
The most commonly used is the principle of Ozone Analyzer is the ultraviolet absorption method, which uses a stable ultraviolet light source to generate ultraviolet rays, and filters other wavelengths of ultraviolet light through a special quartz glass. Only 253.7±1 nm are allowed to pass.
A single stable UV light source can reach the sampling photoelectric transmitter after passing through the highly transparent quartz glass window and the ozone reaction tank.
Through the ratio of the electrical signals(Light intensity) of the sample and the photoelectric sensor that filters ozone-free air, the data can be transmitted after analysis by the management software, we can calculat the ozone concentration.
Ozone generation and treatment technology has a wide range of applications in various industries.
It has the advantages of cleanliness, deodorization, decolorization, sterilization, no residue, and low cost, which is in line with the advantages of green industrial processes.
After the final reaction and half-life of ozone, it will be reduced to oxygen, so there will be no problem of toxic residue.

Specification

Type Standard type(User-range) Standard type(Auto-range)
Measuring range 1000 ppmv / 1% / 20%v/v / Auto-range 1 ... 100 ppm / User-range
Analog output Analog output(Optional) Analog output(Optional)
4 ... 20 mA / DC 0 ... 1 V / DC 1 ... 5 V
(Choose one)
4 ... 20 mA / DC 0 ... 1 V / DC 1 ... 5 V
(Single selection)
Display unit ppm%mg/m3g/m3
at Auto-range
ppbppmmg/m3、μg/m3
at Auto-range
Heat engine time 5 min 5 min
Resolution Min. 0.1 ppmv at 1000 ppm Min. 0.1 ppbv at 1 ppm
Reaction time(T95) 10 sec 40 sec at 500 ppb
Data update speed 0.1 sec ... 100 min 0.1 sec ... 100 min
Data average time 0.1 sec ... 25500 min 0.1 sec ... 25500 min
Data storage
4000 rows of data record
(Max. storage capacity 270 days,
hardware output)
4000 rows of data record
(Max. storage capacity 270 days,
hardware output)
Zero drift Automatic compensation Automatic compensation
Accuracy
(Instrument error)
±2%F.S.(Full scale) Reading±1% at 100 ppb ... 100 ppmv
Provide ISO17025 report traceable to NIST SRP#30
Sample update speed 1 sec ... 24 hr 1 sec ... 24 hr
Detecting unit 254 nm, reduced to 50% after
about 20,000 hours of life
254 nm, reduced to 50% after
about 20,000 hours of life
Sampling &
Calibration flow
1.0 L/min(not included pump) 1.0 ... 1.5 L/min(Built-in pump)
Exterior dimension L250xW200xH62 mm L250xW200xH62 mm
Weight 1.5 kg(Include active carbon) 1.5 kg(Include purification device)
Power supply DC 12 V, 1.5A max.
at AC 100 ... 240 V, 50 / 60 Hz
DC 12 V, 1.5A max.
at AC 100 ... 240 V, 50/60 Hz
Operating Temp. range 0 ... 40°C 0 ... 40°C
Operating pressure range 700 ... 780 mmHg 700 ... 780 mmHg
Digit signal output USB(Temp. / Pressure / Concentration) USB(Temp. / Pressure / Concentration)
Warning signal output LED(Filter clogging/ Light source /
Active carbon / Calibration reminder)
LED(Filter clogging / UV light source /
Ozone purifier / Calibration)


Standard
accessories

 
User manual User manual
Silicone tube(0.5 m) Silicone tube(0.5 m)
B-type USB cable(1 m) B-type USB cable(1 m)
USB to RS-485 one communication line
(User self-calibration)
None
DC 12 V 1.5 A max. 1
voltage transformer
DC 12 V 1.5 A max. 1
voltage transformer
Verification retrospective report Calibration retrospective report
Software CD for user self-calibration None


Optional
accessories

 
Software CD for user self-calibration and
concentration conversion(Advanced version)
Select two correction range
(Calibration fee is extra)
Float ozone resistant
flow controller(0 ... 2 LPM)
Float ozone resistant
flow controller(0 ... 2 LPM)
None Software CDRead, self-calibration,
switching and other functions
Pump DC 110 / 220 V 60 Hz Pump DC 110 / 220 V 60 Hz
None USB to RS-485 communication cable
Self-calibration, switching and other functions

Application
Mainly used in ozone preparation workshop(Ozone generator / ozone plant building, etc.) / Chemicals / Petroleum / Paper / Textile / Pharmaceutical and essence perfume industry / Waterworks / Sewage / Ozone industry / Industrial process water treatment and ozone disinfection testing in pure water industry / Food and medicine sterilization workshops and other occasions

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  

You have 0 items in you cart. Would you like to checkout now?
0 items
Switch to Mobile Version