- Allen-Bradley
- ASHCROFT
- New & Featured Products - HPS high-purity pressure gauge with Reed Switch
- New & Featured Products - S1 Pressure Transducer
- New & Featured Products - ZT12 High Purity Pressure Transmitter
- New & Featured Products - ZX12 High Purity Pressure Transmitter
- Pressure Instruments - Accessories
- Pressure Instruments - Diaphragm Seals-Isolators
- Pressure Instruments - Pressure Gauges
- Pressure Instruments - Pressure Sensors (Transducers/Transmitters)
- Pressure Instruments - Pressure Switches
- Pressure Instruments - SMART Transmitter Assemblies
- Temperature Instruments - MultiPoint Temperature Sensors
- Temperature Instruments - OEM Temperature Sensors
- Temperature Instruments - RTDs
- Temperature Instruments - Temperature Switches
- Temperature Instruments - Thermocouples
- Temperature Instruments - Thermometers
- Temperature Instruments - Thermowells
- Test Instruments - Calibrators
- Test Instruments - Hand Pumps-Controllers
- Test Instruments - Hydraulic Testers
- Test Instruments - Test Gauges
- Cosel
- Euromag
- eYc
- Finetek
- Huba Control
- Koyo
- Maxwell
- MEKKO
- Prokits
- 3C Product Repair Tools
- Aid Tools
- Alignment Tools & Screwdrivers
- Ceramic Driver
- Crimpers
- Cutter
- Drill Bits
- Driver Set
- Electrical Pliers
- Fiber Optics
- Hex Key Wrenches
- Hex Nut Drivers
- Knives & Scissors
- Miscellaneous
- Plier
- Power Tools
- Precision Tweezers
- Punch Down Tools
- Socket Wrenches
- Soldering & Desoldering
- Storage Box
- Strippers
- Test Instruments
- VDE Insulation Tools
- Setra
- Siemens
- SIMEX
- Sondar
- SURE INSTRUMENTS
- Suto
- Tsuruga
- VAISALA
- VE-PURE
- WELTEM
- Winters Instruments
TECH IMPRO AUTOMATION SOLUTION SDN BHD
7263, 1st Floor, Lorong Chempa, 12200 Butterworth, Penang, Malaysia.
+6012-466 1514
eYc FUM05B Wall Mounted Ultrasonic Flowmeter
Previous | 7 / 8 | Next |
Feature :
Measurement accuracy 1 %
Converter protection class IP 67 , transducer protection class IP 68
Wide measurement range , pipe size from DN15mm to DN6000mm
Connect the temperature transducer can finish the heat / energy measurement
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)
Description
Measurement accuracy 1 %
Converter protection class IP 67 , transducer protection class IP 68
Wide measurement range , pipe size from DN15mm to DN6000mm
Connect the temperature transducer can finish the heat / energy measurement
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)
Description
. No need to cut off water , no pressure loss
. Connect clamp on temperature , transducer , can finish the heat / energy measurement
. Easy for installation
FUM05B flow meter can be virtually applied to a wide range of long-term online measurement. Convertor IP67, transducer IP68. A variety of liquid applications can be accommodated: ultra-pure liquids, portable water, chemicals, raw sewage, reclaimed water, cooling water, river water, plant, effluent.etc
Specification
Converter
Principle:
Transit-time Ultrasonic Flowmeter
Accuracy:
± 1 %
Data Interface:
Insulate RS-485, Support the Modbus
Signal Output:
. 4 ... 20 mA , electric resistance 0 ... 1 K , accuracy 0.1 %
. OCT pulse output ( Pulse width ... 1000 ms, the default is 200 ms )
. Relay output
Signal Input:
. 4 ... 20 mA , accuracy 0.1 %
. Connect the temperature transducer Pt100
Display:
2 x 20 character LCD with backlight
Measuring Medium
Type of Liquid:
Single liquid can transmit sound wave such as Water, Oil, Alcohol, Beverage, Ultra-pure liquid, etc.
Temperature:
-30 ... +160 ℃
Turbidity:
≦ 10000 ppm ( less bubble )
Flowrate:
0 ... ± 10 m/s
Pipe Installation Condition
Pipe Material:
Steel, Stainless Steel, Cast Iron, Copper, Cement, Pipe, PVC, Aluminum, Glass steel product, the liner is allowed
Pipe Diameter:
15 ... 6000 mm
Straight Pipe:
Transducer installation should be satisfied: upstream 10 D, downstream 5D, 30D from the pump
Working Environment
Temperature
Converter : -20 ... 60 ℃
Flow Transducer: 30 ... +160 ℃
Humidity:
Converter: 85 %RH
Flow Transducer: Water depth ≦ 2m
Special Cable
Twisted-pair cable, generally, the length under 50 meters; Select the RS-485, transmission
distance can over 1000m
Power Supply
DC 8 ... 36 V
AC 85 ... 264 V
Power Consumption
1.5 W
Dimension
132 x 150 x 85 mm (converter)
Application
Oil and Gas Industries / Chemical / Pharmaceutical / Food and Beverage / Metal / Mining / Pulp and Paper / Wastewater Industries.
Converter
Principle:
Transit-time Ultrasonic Flowmeter
Accuracy:
± 1 %
Data Interface:
Insulate RS-485, Support the Modbus
Signal Output:
. 4 ... 20 mA , electric resistance 0 ... 1 K , accuracy 0.1 %
. OCT pulse output ( Pulse width ... 1000 ms, the default is 200 ms )
. Relay output
Signal Input:
. 4 ... 20 mA , accuracy 0.1 %
. Connect the temperature transducer Pt100
Display:
2 x 20 character LCD with backlight
Measuring Medium
Type of Liquid:
Single liquid can transmit sound wave such as Water, Oil, Alcohol, Beverage, Ultra-pure liquid, etc.
Temperature:
-30 ... +160 ℃
Turbidity:
≦ 10000 ppm ( less bubble )
Flowrate:
0 ... ± 10 m/s
Pipe Installation Condition
Pipe Material:
Steel, Stainless Steel, Cast Iron, Copper, Cement, Pipe, PVC, Aluminum, Glass steel product, the liner is allowed
Pipe Diameter:
15 ... 6000 mm
Straight Pipe:
Transducer installation should be satisfied: upstream 10 D, downstream 5D, 30D from the pump
Working Environment
Temperature
Converter : -20 ... 60 ℃
Flow Transducer: 30 ... +160 ℃
Humidity:
Converter: 85 %RH
Flow Transducer: Water depth ≦ 2m
Special Cable
Twisted-pair cable, generally, the length under 50 meters; Select the RS-485, transmission
distance can over 1000m
Power Supply
DC 8 ... 36 V
AC 85 ... 264 V
Power Consumption
1.5 W
Dimension
132 x 150 x 85 mm (converter)
Application
Oil and Gas Industries / Chemical / Pharmaceutical / Food and Beverage / Metal / Mining / Pulp and Paper / Wastewater Industries.