- Allen-Bradley
- ASHCROFT
- New & Featured Products - HPS high-purity pressure gauge with Reed Switch
- New & Featured Products - S1 Pressure Transducer
- New & Featured Products - ZT12 High Purity Pressure Transmitter
- New & Featured Products - ZX12 High Purity Pressure Transmitter
- Pressure Instruments - Accessories
- Pressure Instruments - Diaphragm Seals-Isolators
- Pressure Instruments - Pressure Gauges
- Pressure Instruments - Pressure Sensors (Transducers/Transmitters)
- Pressure Instruments - Pressure Switches
- Pressure Instruments - SMART Transmitter Assemblies
- Temperature Instruments - MultiPoint Temperature Sensors
- Temperature Instruments - OEM Temperature Sensors
- Temperature Instruments - RTDs
- Temperature Instruments - Temperature Switches
- Temperature Instruments - Thermocouples
- Temperature Instruments - Thermometers
- Temperature Instruments - Thermowells
- Test Instruments - Calibrators
- Test Instruments - Hand Pumps-Controllers
- Test Instruments - Hydraulic Testers
- Test Instruments - Test Gauges
- Cosel
- Euromag
- eYc
- Finetek
- Huba Control
- Koyo
- Maxwell
- MEKKO
- Prokits
- 3C Product Repair Tools
- Aid Tools
- Alignment Tools & Screwdrivers
- Ceramic Driver
- Crimpers
- Cutter
- Drill Bits
- Driver Set
- Electrical Pliers
- Fiber Optics
- Hex Key Wrenches
- Hex Nut Drivers
- Knives & Scissors
- Miscellaneous
- Plier
- Power Tools
- Precision Tweezers
- Punch Down Tools
- Socket Wrenches
- Soldering & Desoldering
- Storage Box
- Strippers
- Test Instruments
- VDE Insulation Tools
- Setra
- Siemens
- SIMEX
- Sondar
- SURE INSTRUMENTS
- Suto
- Tsuruga
- VAISALA
- VE-PURE
- WELTEM
- Winters Instruments
TECH IMPRO AUTOMATION SOLUTION SDN BHD
7263, 1st Floor, Lorong Chempa, 12200 Butterworth, Penang, Malaysia.
+6012-466 1514
eYc FTM06D Thermal Mass Flow Transmitter
Previous | 2 / 3 | Next |
Output:One group output, Analog(4 ... 20 mA / 0 ... 10 V)+RS-485 or Impulse+RS-485
Input:Thermal mass flow sensor
Measuring range:Air:0 ... 120 m/s
Accuracy:Air (at 25°C):±3%F.S.(Option 1.5%)
IP rating:IP65
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA
Description
Input:Thermal mass flow sensor
Measuring range:Air:0 ... 120 m/s
Accuracy:Air (at 25°C):±3%F.S.(Option 1.5%)
IP rating:IP65
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA
Description
- Thermal mass flow sensor
- Can measure air velocity and air volume
- Analog / RS-485 / Impulse output
- Built-in temperature compensation, accurate measurement
- Using constant temperature anemometer(CTA) technology, good sensitivity
-
Display velocity / temperature , Measure cycle display every 3 sec(Light identification)
Unit setting:[m/s], [ft/s], [Nm3/h], [L/min], [°C], [°F]
Output options:0 ... 10 V / 4 ... 20 mA;Pipe setting range:20 ... 9999 mm - Strong stainless steel housing, for a variety of harsh environments
Specification
Type:Thermal mass flow sensor
Range:Air:0 ... 120 m/s
Minimum initial value:0.2 m/s
Installation angle effect:<5% of the measured value (When the installation angle<± 3 degrees)
Signal:One group output, Analog(4 ... 20 mA / 0 ... 10 V)+RS-485 or Impulse+RS-485
Signal connection:3-wire
Product accuracy:Air (at 25°C):±3%F.S.(Option 1.5%)
Warm-up time:About 120 sec
Response time:t90>3 sec
Load resistance:Voltage output:≧ 10 KΩ;Current output:≦ 250 Ω
Medium:Non-corrosive gas
Operating Temp. & Humid.:0 ... 50°C;20 ... 90%RH(Non-condensing)
Storage Temp.:- 20 ... 85°C
Power supply:DC 24 V±10%
Current consumption:24 V:110 mA
Electrical connection:M12 Metal quick connector
Flange or thread:Metal flange mount or R1/2'' metal quick connector
IP rating:IP65(IP67 option)
Electrical protection:■ Polarity protection ■ Over-voltage ■ Short-circuit
Housing:Body&Probe:SUS304, Probe head:PC+Glass fiber
Weight:480 g
Application
Industrial process gas supply / Consumption and dry flow monitoring / Compressed air consumption measurement / Buildings / Factories / Clean rooms / Hospitals / Semiconductors / Electronics / Paper / Printing / Textiles / Steel / Food / Chemicals / Pharmaceuticals / Biotechnology industries
Type:Thermal mass flow sensor
Range:Air:0 ... 120 m/s
Minimum initial value:0.2 m/s
Installation angle effect:<5% of the measured value (When the installation angle<± 3 degrees)
Signal:One group output, Analog(4 ... 20 mA / 0 ... 10 V)+RS-485 or Impulse+RS-485
Signal connection:3-wire
Product accuracy:Air (at 25°C):±3%F.S.(Option 1.5%)
Warm-up time:About 120 sec
Response time:t90>3 sec
Load resistance:Voltage output:≧ 10 KΩ;Current output:≦ 250 Ω
Medium:Non-corrosive gas
Operating Temp. & Humid.:0 ... 50°C;20 ... 90%RH(Non-condensing)
Storage Temp.:- 20 ... 85°C
Power supply:DC 24 V±10%
Current consumption:24 V:110 mA
Electrical connection:M12 Metal quick connector
Flange or thread:Metal flange mount or R1/2'' metal quick connector
IP rating:IP65(IP67 option)
Electrical protection:■ Polarity protection ■ Over-voltage ■ Short-circuit
Housing:Body&Probe:SUS304, Probe head:PC+Glass fiber
Weight:480 g
Application
Industrial process gas supply / Consumption and dry flow monitoring / Compressed air consumption measurement / Buildings / Factories / Clean rooms / Hospitals / Semiconductors / Electronics / Paper / Printing / Textiles / Steel / Food / Chemicals / Pharmaceuticals / Biotechnology industries