- Allen-Bradley
- ASHCROFT
- New & Featured Products - HPS high-purity pressure gauge with Reed Switch
- New & Featured Products - S1 Pressure Transducer
- New & Featured Products - ZT12 High Purity Pressure Transmitter
- New & Featured Products - ZX12 High Purity Pressure Transmitter
- Pressure Instruments - Accessories
- Pressure Instruments - Diaphragm Seals-Isolators
- Pressure Instruments - Pressure Gauges
- Pressure Instruments - Pressure Sensors (Transducers/Transmitters)
- Pressure Instruments - Pressure Switches
- Pressure Instruments - SMART Transmitter Assemblies
- Temperature Instruments - MultiPoint Temperature Sensors
- Temperature Instruments - OEM Temperature Sensors
- Temperature Instruments - RTDs
- Temperature Instruments - Temperature Switches
- Temperature Instruments - Thermocouples
- Temperature Instruments - Thermometers
- Temperature Instruments - Thermowells
- Test Instruments - Calibrators
- Test Instruments - Hand Pumps-Controllers
- Test Instruments - Hydraulic Testers
- Test Instruments - Test Gauges
- Cosel
- Euromag
- eYc
- Finetek
- Huba Control
- Koyo
- Maxwell
- MEKKO
- Prokits
- 3C Product Repair Tools
- Aid Tools
- Alignment Tools & Screwdrivers
- Ceramic Driver
- Crimpers
- Cutter
- Drill Bits
- Driver Set
- Electrical Pliers
- Fiber Optics
- Hex Key Wrenches
- Hex Nut Drivers
- Knives & Scissors
- Miscellaneous
- Plier
- Power Tools
- Precision Tweezers
- Punch Down Tools
- Socket Wrenches
- Soldering & Desoldering
- Storage Box
- Strippers
- Test Instruments
- VDE Insulation Tools
- Setra
- Siemens
- SIMEX
- Sondar
- SURE INSTRUMENTS
- Suto
- Tsuruga
- VAISALA
- VE-PURE
- WELTEM
- Winters Instruments
TECH IMPRO AUTOMATION SOLUTION SDN BHD
7263, 1st Floor, Lorong Chempa, 12200 Butterworth, Penang, Malaysia.
+6012-466 1514
eYc AFMT Average Flow Measuring Tube ( Pitot tube )
Previous | 7 / 10 | Next |
Feature:High temperature resistance Corrosion resistant, Anti-clogging Data convert to flow rate quickly
Duct-mounting type / Material:Stainless 316
Operating temperature:Max. 250°C
Length:4'' ... 40''(100 ... 1000 mm)
Option:differencial pressure trainsmitter(Can measure flow)
Description
AFMT is a probe we inserted into the duct(along with the whole diameter) to measure the flow. When the probe encounters the flow, will sense and get the average total pressure P1 in windward side and static pressure P2 in leeward. AFMT then gets the flow velocity by measuring the difference between total pressure and static pressure(i.e.) dynamic pressure(∆P) and flow average velocity(V).
Specification
Measuring Media : Air
Operating pressure : Max.10 bar
Operating temperature : Max.250°C
Installation connection : 4 ... 12'' below 3/4'' PT movable thread
18 ...40 '' below 1'' PT movable thread
Exit connection : 1/8'' G inside thread or 1/4'' G inside thread
Measuring material : Stainless steel 316
Connection thread material : Copper or stainless steel (optional)
Application
Ventilation pipes / Flue industry / Exhaust gas emission / Environmental protection engineering / Air conditioning systems / Vacuum cleaning / Especially high temperature and chimney, wind speed measurement of dusty air and high flow rate in environmental testing
Duct-mounting type / Material:Stainless 316
Operating temperature:Max. 250°C
Length:4'' ... 40''(100 ... 1000 mm)
Option:differencial pressure trainsmitter(Can measure flow)
Description
- Stainless steel housing, high temperature resistant, corrosion resistance, dust resistance, can measure micro flow rates
- If connect with eYc micro differential transmitter PHM33 or PMD33 with Multi-function display SD06 or DPM02 is a great solution for measure the dynamic pressure(ΔP) of the airflow in the pipeline and calculate the wind speed, air volume and temperature
-
Applied in harsh environments, exhaust gas emission, environmental protection engineering, installation location is not restricted
※Can be customized according to customer needs
AFMT is a probe we inserted into the duct(along with the whole diameter) to measure the flow. When the probe encounters the flow, will sense and get the average total pressure P1 in windward side and static pressure P2 in leeward. AFMT then gets the flow velocity by measuring the difference between total pressure and static pressure(i.e.) dynamic pressure(∆P) and flow average velocity(V).
Specification
Measuring Media : Air
Operating pressure : Max.10 bar
Operating temperature : Max.250°C
Installation connection : 4 ... 12'' below 3/4'' PT movable thread
18 ...40 '' below 1'' PT movable thread
Exit connection : 1/8'' G inside thread or 1/4'' G inside thread
Measuring material : Stainless steel 316
Connection thread material : Copper or stainless steel (optional)
Application
Ventilation pipes / Flue industry / Exhaust gas emission / Environmental protection engineering / Air conditioning systems / Vacuum cleaning / Especially high temperature and chimney, wind speed measurement of dusty air and high flow rate in environmental testing