Max. scaling range : Dew point£º-100 ... +60 dp°C
Linear accuracy : ±1 dp°C (at -20 ... +20 dp°C)
±1.5 dp°C(at -40 ... +20 dp°C)
±2 dp°C (at -60 dp°C)
Reference (at -100 ... -60 dp°C)
Power supply : DC 24 V±15%
Installation : 1/2’’PT, 1/2’’G, and 5/8’’UNF
IP rating : IP65(Probe£ºIP20)
¡ñYUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation£º3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA
 
Description

-Features

Dew point calibration, highly accuracy, 4 ... 20 mA and RS-485 output
Reduce insensitivity temperature zone, quickly response
Hysteresis compensation, resistance to moisture, extreme high and low humidity impact
EMC anti-interference, anti-condensation, low-temperature influence, long-term stability
Three thread (1/2’’PT, 1/2’’G, and 5/8’’UNF) mode can be selected
 
Specification

Input
Input type : Capacitive humidity sensor & Pt100
Operating range of dew point : -100 ... +60 dp°C

Output
Max. scaling range : Dew point£º-100 ... +60 dp°C
Dew point switch to another physical quantity range : 
                                                                                    Frost point£º-60 ... 0 fp°C
                                                                                    Absolute humid.(Volume)0 ... 50000 ppm/v
                                                                                    Absolute humid.(Weight)0 ... 50000 ppm/w
Output signal : Standard RS-485 & 1 analog output 4 ... 20 mA / 0 ... 10 V
Signal connection : 3-wire
Linear accuracy : ±1 dp°C (at -20 ... +20 dp°C)
                             ±1.5 dp°C(at -40 ... +20 dp°C)
                             ±2 dp°C (at -60 dp°C)
                             Reference (at -100 ... -60 dp°C)
Load resistance : Current output£ºMax.500 Ω£»Voltage output£ºMin.10 KΩ

Electrical
Power supply : DC 24 V±15%
Current consumption : DC 24 V, 50 mA
Electrical connection : M12 connector

Environment
Output calibration (ZERO & SPAN) adjustment range : Software 
Response time t90(Temp. at+25°C) : £¼20 sec
Medium : Air
Operating Temp. for housing : -40 ... +60°C
Operating Humid. for housing : 0 ... 95%RH (Non-condensing)
Operating Temp. for probe : -40 ... +60°C
Storage temperature : -25 ... +60°C
Pressure resistance : 16 bar

Installation
Installation : 1/2’’PT, 1/2’’G, and 5/8’’UNF

Protection
IP rating : IP65(Probe£ºIP20)
Electrical protection : ¡ö Polarity protection ¡ö Over-voltage ¡ö Short-circuit

Material
Housing : S.S.(SUS304)
Probe : S.S.(SUS304)£»SUS sintered filter(SUS316)
Weight : 168 g
 
Application
Compressed air system / Air separation equipment / Freezer / Adsorption machine / Plastic dryer / Industrial drying process / Paper / Chemical process monitoring
 
Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  

You have 0 items in you cart. Would you like to checkout now?
0 items
Switch to Mobile Version