- Allen-Bradley
- ASHCROFT
- New & Featured Products - HPS high-purity pressure gauge with Reed Switch
- New & Featured Products - S1 Pressure Transducer
- New & Featured Products - ZT12 High Purity Pressure Transmitter
- New & Featured Products - ZX12 High Purity Pressure Transmitter
- Pressure Instruments - Accessories
- Pressure Instruments - Diaphragm Seals-Isolators
- Pressure Instruments - Pressure Gauges
- Pressure Instruments - Pressure Sensors (Transducers/Transmitters)
- Pressure Instruments - Pressure Switches
- Pressure Instruments - SMART Transmitter Assemblies
- Temperature Instruments - MultiPoint Temperature Sensors
- Temperature Instruments - OEM Temperature Sensors
- Temperature Instruments - RTDs
- Temperature Instruments - Temperature Switches
- Temperature Instruments - Thermocouples
- Temperature Instruments - Thermometers
- Temperature Instruments - Thermowells
- Test Instruments - Calibrators
- Test Instruments - Hand Pumps-Controllers
- Test Instruments - Hydraulic Testers
- Test Instruments - Test Gauges
- Cosel
- Euromag
- eYc
- Finetek
- Huba Control
- Koyo
- Maxwell
- MEKKO
- Prokits
- 3C Product Repair Tools
- Aid Tools
- Alignment Tools & Screwdrivers
- Ceramic Driver
- Crimpers
- Cutter
- Drill Bits
- Driver Set
- Electrical Pliers
- Fiber Optics
- Hex Key Wrenches
- Hex Nut Drivers
- Knives & Scissors
- Miscellaneous
- Plier
- Power Tools
- Precision Tweezers
- Punch Down Tools
- Socket Wrenches
- Soldering & Desoldering
- Storage Box
- Strippers
- Test Instruments
- VDE Insulation Tools
- Setra
- Siemens
- SIMEX
- Sondar
- SURE INSTRUMENTS
- Suto
- Tsuruga
- VAISALA
- VE-PURE
- WELTEM
- Winters Instruments
TECH IMPRO AUTOMATION SOLUTION SDN BHD
7263, 1st Floor, Lorong Chempa, 12200 Butterworth, Penang, Malaysia.
+6012-466 1514
COSEL AME800F
Previous | 19 / 28 | Next |
Rated Input: 85 - 264VAC 1Φ
Rated Output Wattage: 800W
Slots: 6
Rated Output Voltage: 3.3V,5V,7.5V,12V,15V,24V,36V,48V,24V/24V
• Low profile(41mm, 1.61inch=meet to 1U height)
• Universal input (85-264VAC)
• For medical electrical equipment
¡¡(ANSI/AAMI ES60601-1, EN60601-1 3rd, IEC60601-1-2 4th Ed.)
• Medical Isolation Grade 2MOPP
• With AUX output 5V 1A
• Global Inhibit, Remote ON/OFF control, alarm
• Output connector is available (Option: -J2£©
• Monitoring function and some parameter changes by communication are available(Option: -I3, -I).
Please refer to Configuration-Model Name Construction in Instruction manual for Order Name.
Order Name is required to create by the above menu.
¡öModel Name
(2£© Abbreviation for output power of AME series
08: AME800F(AM08£©
(3£© Slot 6 Output module
(4£© Slot 5 Output module
(5£© Slot 4 Output module
(6£© Slot 3 Output module
(7£© Slot 2 Output module
(8£© Slot 1 Output module
(9£© Parallel code
(10£©Series code
(11) Option
A: 12V/0.1A AUX instead of 5V1A
R: Reversed logic remote on/off
J2: Output connector type
J3: CN1/CN2/CN3 Molex connectors
C: with Coating
F3: Revers air exhaust type
G: Low leakage current
I3: with Extented-UART interface
I: with PMBus interface
Refer to instruction manual 6.1
*The number of slot is different depending on the model.
*The code for empty slot is ''O''
Rated Output Wattage: 800W
Slots: 6
Rated Output Voltage: 3.3V,5V,7.5V,12V,15V,24V,36V,48V,24V/24V
Features of AME800F
• Flexible modular system architecture provides various output configuration• Low profile(41mm, 1.61inch=meet to 1U height)
• Universal input (85-264VAC)
• For medical electrical equipment
¡¡(ANSI/AAMI ES60601-1, EN60601-1 3rd, IEC60601-1-2 4th Ed.)
• Medical Isolation Grade 2MOPP
• With AUX output 5V 1A
• Global Inhibit, Remote ON/OFF control, alarm
• Output connector is available (Option: -J2£©
• Monitoring function and some parameter changes by communication are available(Option: -I3, -I).
Ordering Information and Options
The AME series has Order Name which is used for the ordering aside from Model Name.Please refer to Configuration-Model Name Construction in Instruction manual for Order Name.
Order Name is required to create by the above menu.
¡öModel Name
AM(1£©¡¡¡õ(2£©¡¡-¡¡¡õ(3£©¡¡¡õ(4£©¡¡¡õ(5£©¡¡¡õ(6£©¡¡¡õ(7£©¡¡¡õ(8£©¡¡-¡¡¡õ¡õ(9£©¡õ¡õ(10¡¡-¡¡¡õ(11)¡¡
(1£© Abbreviation for series name of AME series(2£© Abbreviation for output power of AME series
08: AME800F(AM08£©
(3£© Slot 6 Output module
(4£© Slot 5 Output module
(5£© Slot 4 Output module
(6£© Slot 3 Output module
(7£© Slot 2 Output module
(8£© Slot 1 Output module
(9£© Parallel code
(10£©Series code
(11) Option
A: 12V/0.1A AUX instead of 5V1A
R: Reversed logic remote on/off
J2: Output connector type
J3: CN1/CN2/CN3 Molex connectors
C: with Coating
F3: Revers air exhaust type
G: Low leakage current
I3: with Extented-UART interface
I: with PMBus interface
Refer to instruction manual 6.1
*The number of slot is different depending on the model.
*The code for empty slot is ''O''
Specification
Input Module
Contents | Specifications | ||
---|---|---|---|
Input Voltage | 85 - 264VAC 1Φ * | ||
Output | Number of Slot | 6 | |
Total Output power | AC90 - 150V | 600W | |
AC170 - 264V | 800W | ||
Operating Temperature/Humidity | -20 to +70¡æ, 20 - 90%RH (Non condensing£© * | ||
Safety And Noise Regulations | Agency Approvals (At only AC input) |
UL62368-1, C-UL £¨CSA62368-1£©, EN62368-1, ANSI/AAMI ES60601-1, EN60601-1 3rd , Complies with IEC60601-1-2 4th Ed. |
|
Conducted Noise | Complies with FCC-B, VCCI-B,CISPR11-B, CISPR32-B, EN55011-B, EN55032-B | ||
High Attenuation | Complies with IEC61000-3-2 * | ||
Others | Dimensions (WxHxD) | 127×41×257mm | |
Weight | 1.8kg max | ||
Cooling Method | Forced cooling (internal fan£© | ||
Warranty Period | 5-year (Refer to Instruction Manuals£© |